Viper AS380/15C-EU (50000201) [6/150] Maintenance

Viper AS380/15B-EU(50000199) [6/150] Maintenance
USER MANUAL
5
MACHINE NOT BEING USED FOR LONG PERIODS
If the machine is not going to be used for more than 30days, please proceed with below actions:
1. Perform the procedures shown in ‘After Using the Machine paragraph’.
2. Disconnect the AC cable(16).
MAINTENANCE
The lifespan of the machine and its maximum operating safety are ensured by correct and regular
maintenance. The following chart provides the scheduled maintenance. The intervals shown may vary
according to particular working conditions, which will be defined by the person in charge of the
maintenance.
WARNING
Maintenance procedures must be sure the cable unplug from outlet .
Moreover, carefully read the instruction in the Safety chapter.
All scheduled or extraordinary maintenance procedures must be performed by qualified personnel, or by
an authorized Service Center.
This Manual describes only the easier and most common maintenance procedures.
For other maintenance procedures shown in the Scheduled Maintenance Table, refer to the Service
Manual that can be consulted at any Service Center.
SCHEDULED MAINTENANCE TABLE
Procedure Daily, after using
the machine
Weekly Every six
mouths
yearly
Squeegee cleaning
Brush cleaning
Tank and vacuum grid with float cleaning, the
cover gasket check
Squeegee blade check and replacement
Solution filter cleaning
Out-water pipe filter cleaning
Screw and nut tightening check (1)
Lubricate rotary parts
(1)
Brush/Pad-holder motor carbon brush check or
replacement
(2)
Vacuum system motor carbon brush check or
replacement
(2)
(1) And after the first 8 working hours.
(2) This maintenance procedure must be performed by an authorized viper Service Center.
SQUEEGEE CLEANING
NOTE
The squeegee must be clean and its blades must be in good condition in order to
getting a good drying performance.