Sdmo PERFORM 4500XL [13/24] Storing the generating set

Sdmo PERFORM 4500XL [13/24] Storing the generating set
8. Storing the generating set
If the generating set is not used for a long period of time, it must be stored in accordance with the guidelines given below.
n Open the fuel tap (fig. A - No. 5 & fig. C - No. 1) to “I”.
o Start the generating set and allow it to run till it stops due to lack of fuel.
p Close the fuel tap to “0”.
q While the engine is still hot, change the engine oil (see § Renewing the engine oil).
r Remove the spark plug (fig. F - No. 2) (see § Checking the spark plug) and pour a maximum of 15 ml of engine oil into the cylinder
through the spark plug port before refitting the spark plug.
s Without starting the engine, slowly pull the recoil starter handle (fig. A - No. 8) until you feel a certain resistance.
t Clean the outside of the generating set, apply an anti-rust product on the damaged parts and cover it up with an all-weather dust
cover to protect it from dust.
u Store the generating set in a clean, dry place.
9. Troubleshooting
Problems Probable causes Possible solutions
Engine not
starting
Load connected to the generating set during start-up. Disconnect the load.
Start and Stop control (fig. A - No. 7) “O” or “OFF”. Set the Start and Stop control to “I” or “ON”.
Oil level too low.
Check the oil level and top up if necessary
(see § Checking the oil level).
Fuel tap (fig. A - No. 5) closed. Open the fuel tap.
Fuel level too low. Fill up with fuel (see § Filling with fuel).
Fuel strainer (fig. A - No. 4) blocked.
Clean the fuel strainer (see § Cleaning the fuel
strainer).
Air filter (fig. A - No. 12) blocked. Clean the air filter (see § Cleaning the air filter).
Defective spark plug (fig. F - No. 2).
Check the spark plug (see § Checking the spark plug)
and replace if necessary.
Fuel supply blocked or leaking. Have it checked, repaired or replaced.*
Engine stopped
Oil level too low.
Check the oil level and fill-up if necessary
(see § Checking the oil level).
Fuel level too low. Fill up with fuel (see § Filling with fuel).
Blocked ventilation inlets.
Clean the generating set (see § Cleaning the
generating set).
No electric
current
Circuit breaker (fig. A - No. 9) not actuated. Actuate the circuit breaker.
Defective appliance supply cord. Change the cord.
Defective electrical sockets (fig. A - No. 10). Have it checked, repaired or replaced.*
Defective alternator. Have it checked, repaired or replaced.*
Triggering of
circuit breakers
Device connected or faulty cord. Disconnect the device and the cord.
Overload (see § Capacity of the generating set). Remove the overload.
* Operation(s) to be entrusted to one of our agents.