Sdmo PERFORM 4500XL Руководство пользователя онлайн [7/24] 500944
![Sdmo PERFORM 4500XL Руководство пользователя онлайн [7/24] 500944](/views2/1510432/page7/bg7.png)
1.3.4 Safety guidelines to prevent fire
Never operate the generating set in areas containing flammable products (risk of sparks).
Keep all flammable products (petrol, oil, fabric etc.) out of the way when the unit is in
operation.
Never cover the generating set with any type of material while it is in operation or just after
it has been turned off: always wait until the engine cools down.
Danger
1.3.5 Safety guidelines against burns
Never touch the engine or the silencer while the generating set is in operation, or when it has just stopped.
Warning
Hot oil burns; avoid contact with the skin. Before carrying out any operation, check that the system is no longer pressurised. Never start
or run the engine if the oil filler cap is off (oil may splash out).
1.3.6 Danger of moving parts
Never go near a moving part that is in operation if you have loose clothing or long hair that
is not enclosed in a protective hair net.
Do not try to stop, slow down or impede a moving part when it is in operation.
Dange
r
1.3.7 Safety guidelines for exhaust gases
The carbon monoxide present in the exhaust gas may lead to death by inhalation if the
concentration levels in the atmosphere are too high.
Always use the generating set in a well ventilated area where the gases cannot
accumulate.
Danger
For safety reasons and for correct operation of the generating set, correct ventilation is essential (risk of intoxication, engine
overheating and accidents involving, or damage to, the surrounding equipment and property). If it is necessary to operate it inside a
building, the exhaust gases must be evacuated outside and adequate ventilation must be provided so that any people or animals
present are not affected.
1.3.8 Operating conditions
The stated outputs of the generating sets are obtained under the reference conditions outlined in ISO 8528-1(2005):
9 Total barometric pressure: 100 Kpa
9 Air ambient temperature: 25°C (298K)
9 Relative humidity: 30%
Generating set performance is reduced by approximately 4% for every additional 10° C and/or approximately 1% for every additional
100m in altitude.
1.3.9 Capacity of the generating set (overload)
Never exceed the rated load of the generating set (in Amps and/or Watts) when it is running continuously.
Before connecting and operating the generating set, calculate the electrical power required by the electric appliances (in Watts). This
electrical power rating is usually found on the manufacturer's plate on bulbs, electrical appliances, motors etc. The sum total of power
required by these appliances should not exceed the nominal power rating of the generating set.
1.3.10 Protecting the environment
Drain the engine oil into a designated container: never drain or discard engine oil onto the ground.
As far as possible, avoid sound reverberating through walls or buildings (the noise will be amplified).
If the generating set is used in wooded, bushy or uncultivated areas and if the exhaust silencer is not fitted with a spark arrester, clear
any vegetation away from the area and take care that the sparks do not cause a fire.
1.3.11 Filling with fuel
The fuel is highly flammable and its vapours are combustible.
Filling should be carried out with the engine turned off. Smoking, using a naked flame or
producing sparks are forbidden while the fuel tank is being filled.
All traces of fuel should be wiped off with a clean cloth.
Danger
Storage and handling of petroleum products must be carried out in accordance with the law. Close the fuel tap (if fitted) each time the
tank has been filled. Never top up fuel when the generating set is in operation or hot.
Always place the generating set on a flat, level and horizontal surface to avoid fuel spilling onto the motor. Fill the tank with a funnel
taking care not to spill the fuel, then screw the plug back onto the fuel tank.
Содержание
- 3 3 5 5 2 2 2 2 1 1 7 7 3 3 4 4 0 0 1 1 _ _ 2 2 _ _ 1 1 1
- P p p e e e r r r f f f o o o r r r m m m 3 3 3 0 0 0 0 0 0 0 0 0 1
- Contents 5
- Instructions and safety regulations 5
- Pictograms and plates on the generating sets and what they mean 5
- Preface 1 recommendations 5
- Checking the oil level 8
- Description 8
- Earthing the generating set 8
- Preparation before use 3 positioning the generating set for operation 8
- Checking the air filter 9
- Checking the fuel level 9
- Operation 9
- Starting procedure 9
- Using the generator set 9
- Circuit breaker 10
- Maintenance schedule 6 reminder of use 10
- Maintenance table 10
- Safety features 5 oil cut out 10
- Switching off 10
- Cleaning the fuel strainer 11
- Cleaning the sediment bowl 11
- Maintenance procedures 7 checking bolts nuts and screws 11
- Renewing the engine oil 11
- Checking the spark plug 12
- Cleaning the air filter 12
- Cleaning the generating set 12
- Cleaning the spark arrester 12
- Storing the generating set 13
- Troubleshooting 13
- Cable sizes 14
- Ec declaration of conformity 14
- Specifications 14
- Правила техники безопасности 15
- Предварительная информация 1 рекомендации 15
- Символы и таблички на генераторных установках и их значение 15
- Содержание 15
- Заземление генераторной установки 18
- Описание генераторной установки 18
- Подготовка перед применением 3 место эксплуатации 18
- Проверка уровня масла 18
- Проверка воздушного фильтра 19
- Проверка уровня топлива 19
- Процедура запуска 19
- Работа установки 19
- Эксплуатация генераторной установки 19
- Выключатель 20
- Выключение установки 20
- Защитные устройства 5 устройство безопасности системы смазки 20
- Порядок технического обслуживания 6 напоминание 20
- Таблица обслуживания 20
- Замена моторного масла 21
- Операции технического обслуживания 7 проверка винтовых соединений 21
- Очистка стакана отстойника 21
- Очистка топливного фильтра 21
- Очистка воздушного фильтра 22
- Очистка генераторной установки 22
- Очистка искрогасителя 22
- Проверка свечи зажигания 22
- Устранение незначительных неисправностей 23
- Хранение генераторной установки 23
- Декларация соответствия нормам ес 24
- Сечение проводов 24
- Характеристики 24
Похожие устройства
- Sdmo PERFORM 3000XL Руководство пользователя
- Grost HED 10/20 (101471) Инструкция по эксплуатации
- Dewalt DCG406N Инструкция по эксплуатации
- Karcher 10921040 1.092-104.0 Инструкция по эксплуатации
- Hammer AMD3.6Li USB Инструкция по эксплуатации
- Bosch Quigo III (0603663522) Инструкция по эксплуатации
- Electrolux ECH/AS -2000 ER Инструкция по эксплуатации
- Electrolux ECH/AS -1500 ER Инструкция по эксплуатации
- Electrolux ECH/AS -1000 ER Инструкция по эксплуатации
- Electrolux ECH/T-2000 E Инструкция по эксплуатации
- Electrolux ECH/T-1500 E Инструкция по эксплуатации
- Electrolux ECH/T-1000 E Инструкция по эксплуатации
- STOUT SVB-0003-000015 Инструкция по эксплуатации
- ORAS 267043 Инструкция по эксплуатации
- Grohe Cube Ceramic 3947400H Инструкция по эксплуатации
- Grohe Cube Ceramic 3938600H Инструкция по эксплуатации
- Euro-lift KCD 19833 Инструкция по эксплуатации
- Condtrol Paint Pro (3-7-051) Инструкция по эксплуатации
- Condtrol Paint Check Инструкция по эксплуатации
- Chicago Pneumatic CP6773- D18D Инструкция по эксплуатации
Скачать
Случайные обсуждения