BEHA-AMPROBE HD110C [2/3] Ac volts 45 hz to 2 khz

BEHA-AMPROBE HD110C [2/3] Ac volts 45 hz to 2 khz
HD110C ELECTRICAL SPECIFICATIONS
DC Volts
Ranges 200 mV, 2 V, 20 V, 200 V, 1500 V
Resolution 0.1 mV
Accuracy ±(0.1 % rdg+2 dgts)
Input Impedance 10 MΩ
OL Protection 1500 V dc/1000 V ac rms
Transient Protection
12 kV impulse (1.2 μS/50 μS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should
not be used in installations where transients exceed 12 kV.
AC Volts (45 Hz to 2 kHz)
Ranges 200 mV, 2 V, 20 V, 200 V, 1000 V
Resolution 0.1 mV
Accuracy
200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts)
200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts)
1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts)
1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts)
Input Impedance 10 MΩ
OL Protection 1500 V dc/1000 V ac rms
Transient Protection
12 kV impulse (1.2 μS/50 μS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should
not be used in installations where transients exceed 12 kV.
DC Current
Ranges 200 μA, 2 mA, 20 mA, 200 mA, 2 A
Resolution 0.1 μA
Accuracy
200 μA to 20 mA ±(0.5 % rdg+2 dgts)
200 mA to 2 A ±(1.0 % rdg+2 dgts)
DC Current (cont.)
Voltage Burden
250 mV max. (1 mV/1 μA on 200 μA Range)
(100 mV/1 mA on 2 mA Range)
(10 mV/1 mA on 20 mA Range)
(1.5 mV/1 mA on 200 mA Range)
(500 mV/1 A on 2 A Range)
OL Protection A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic) (FP 700)
AC Current (45 Hz to 1 kHz)
Ranges 200 μA, 2 mA, 20 mA, 200 mA, 2 A
Resolution 0.1 μA
Accuracy
200 μA to 20 mA ±(0.8 % rdg+4 dgts)
200 mA to 2 A ±(1.2 % rdg+4 dgts)
Voltage Burden 250 mV max. (1 V on 2 A range)
OL Protection same as DC Current
www.beha-amprobe.com
For detailed specifications and ordering info go to www.beha-amprobe.com
©2014 Beha-Amprobe. All rights reserved.