AXIOMET AX-160IP [9/30] Function description
![AXIOMET AX-160IP [9/30] Function description](/views2/1664704/page9/bg9.png)
3. FUNCTION DESCRIPTION
3.1. General Functions
3.1.1. DATA HOLD mode
Data Hold mode makes the meter stop updating the displaying. If you want to exit this mode, you can
change the measurement which you need.
1.Touch the key 5 once. Fixes the display on the current value, the symbol H is displayed on the screen.
2. A second touch to return the normal mode.
NOTE:
If you manually change the measurement range after entering the Data Hold modes, the meter exits this
mode.
3.1.2. Manual range and Autorange mode
The meter has both manual range and autorange options.
* In the autorange mode, the Meter selects the best range for the input detected. This allows you to switch
test points without having to reset the range.
* In the manual range mode, you can select the range. This allows you to override autorange and lock the
meter in a specific range.
* The meter defaults to the autorange mode in measurement functions that have more than one range.
When the Meter is in the autorange mode, the symbol AUTO that is displayed on the screen.
To enter and exit the manual range mode:
1.Touch RANGE key 2. The meter enters the manual range mode. And then “MANU” will be displayed on
the LCD.
2.Touch the key 5 or 7 to select range you neeed.
3.Touch RANGE key again to exit. The meter returns to the autorange mode and AUTO is displayed.
3.1.3. Max/Min function
The Meter will display Maximum or Minimum reading at the sub-display area.
Press MAX/MIN key 4 , Maximum reading will display at the sub-display area.
Press again MAX/MIN key 4 , Minimum reading will display at the sub-display area.
Press again MAX/MIN key 4 , device will escape the MAX/MIN mode.
3.1.4. Relative measurement mode
The Meter will display relative measurement in all functions in addition to frequency.
To enter and exit the relative measurement mode:
1. With the Meter in the desired function, touch the test leads to the circuit on which you want future
measurement to be based.
2. Touch REL� key to store the measured value and activate the relative measurement mode. The differ-
Содержание
- Ax 160ip touch pad digital multimeter user s manual 1
- General instructions 1
- Precautions safety measures 1
- Instructions 3
- Symbols 3
- Description 5
- Instrument familiarization 5
- Lcd display 2 auxiliary function key pads 5
- Lcd display 6
- Touch pad 7
- Function description 9
- General functions 9
- Measurement functions 13
- Connect the test leads tip in parallel with the circuit to be measured and don t touch any electrical conductors 5 touch mvhz key 11 again to exit 21
- In noisy environment it is preferable to use shield cable for measuring small signal 21
- General specifications 25
- Pc link 25
- Technical specifications 25
- Measurement specifications 26
- Battery replacement 29
- Fuse replacement 29
- General maintenance 29
- Maintenance 29
- Accessories 30
Похожие устройства
- AXIOMET AX-155 Инструкция
- AXIOMET AX-155 Расширенная инструкция
- AXIOMET AX-150 Расширенная инструкция
- AXIOMET AX-150 Инструкция
- AXIOMET AX-105 Инструкция
- AXIOMET AX-105 Расширенная инструкция
- AXIOMET AX-102 Инструкция
- AXIOMET AX-102 Расширенная инструкция
- AXIOMET AX-T520 Инструкция
- AXIOMET AX-T520 Расширенная инструкция
- AXIOMET AX-PDM01 Инструкция
- Daikin EUWYN5KAZW1 Технические данные
- AXIOMET AX-MS8250 Инструкция
- AXIOMET AX-MS8250 Расширенная инструкция
- Daikin EUWYN5KAZW1 Руководство по эксплуатации
- Daikin EUWYP5KAZW1 Технические данные
- Daikin EUWYP5KAZW1 Руководство по эксплуатации
- Daikin EUWYB5KAZW1 Технические данные
- Daikin EUWYB5KAZW1 Руководство по эксплуатации
- Daikin EUWYN8KAZW1 Технические данные