The height character “H” on the screen will blink showing the next measurement to take. Press READ key to
take height measurement, the result will be displayed on upper portion of screen. (Step 3);
Then the volume is automatically displayed on the lower portion of the screen;
Pressing the READ key again will toggle back and forth between the length, width and height measurement
on the upper portion of the screen;
Press MODE key to clear the data on the portion of the screen, and then can begin the new calculationof
volume;
To choose measurement mode, press MODE key again.
Tips
Press the MODE key one by one will toggle back and forth between the length, area, volume and length mea-
surement. If there are datum on the display, first pressing the MODE key will clear the current datum, and the
mode will be invariable.
4.8. Addition of volumes under volume mode:
Press M key to save the calculated volume of first time measurement, and the “M+” icon will appear on LCD;
Press MODE key to clear the current displayed data, then can begin the second time measurement and
computation (Follow step 1 to 3 under the volume section);
After getting the calculated volume of second time, press +/= key to enter the addition mode. A “+” icon
would appear on LCD;
Press RM key to recall the first calculated volume for the addition. The “M+” icon will disappear and the
stored memory will be automatically cleared;
Press +/= key, the sum of both volumes is shown on the lower portion of the screen;
Repeat the steps above to keep adding the measured volume.
4.9. Temperature display
Press and hold MODE key and at the same time press the RM key, the environment temperature will appear
on the lower portion of screen (the unit is °C if the distance unit is M, while the unit is °F if the distance unit is
ft/in), and press the READ key again to return the measuring state.
4.10. Stud detect
Press the “k” button to the ”DETECTOR” location, the tool will enter detection state and wait to detect.
5. Calibration
5.1.
The tool should be calibrated on the surface of the detected object before detecting or after function “D” switch’s
diversion.