Fluke FLK-1555FC/IR [35/50] Program a test voltage

Fluke FLK-1555FC/IR [35/50] Program a test voltage
Insulation Tester
Measurements
17
Note
The actual test voltage can be up to 10 % higher than the selected test
voltage.
Program a Test Voltage
To set a test voltage in between the preset test voltages, proceed as follows:
1. With the Tester turned on, push to select TEST VOLTAGE.
Test Voltage Display
GHH05.EPS
2. Push or to scroll through the preset test voltage options (250 V,
500 V, 1000 V, 2500 V, 5000 V, and 10,000 V). Select the voltage closest
to the level required.
3. The selected test voltage appears in the upper-right of the display.
4. Push . TVxxxxV appears flashing in the lower-left of the display.
5. Push or to increment and decrement the voltage. When the
correct voltage level shows, do not push . Doing so will return the test
voltage to the next lowest last preset voltage selection. Instead, push
to go to the function menu.
Note
The test voltage can be up to 10 % higher than the test voltage you
select.

Содержание

Скачать