Model No. Output Tol. R&N Effi.
ESP-120-13.5 13.5V, 0~8A ±2% 120mV 81%
ESP-120-27 27V, 0~4A ±1% 150mV 83%
ESP-120-54 54V, 0~2A ±1% 400mV 84%
Model No. Output Tol. R&N Effi.
ENP-120-12 13.8V, 0~8.7A ±1% 150mV 89.5%
ENP-120-24 27.6V, 0~4.3A ±1% 150mV 91%
ENP-120-48 55.2V, 0~2.2A ±1% 350mV 91.5%
Model No. Output Tol. R&N Effi.
ENP-180-12 13.8V, 0~13A ±1% 150mV 91%
ENP-180-24 27.6V, 0~6.5A ±1% 150mV 93.5%
ENP-180-48 55.2V, 0~3.3A ±1% 350mV 94%
Model No. Output Tol. R&N Effi.
ENP-240-12 13.8V, 0~17.4A ±1% 150mV 91%
ENP-240-24 27.6V, 0~8.7A ±1% 150mV 93.5%
ENP-240-48 55.2V, 0~4.4A ±1% 350mV 94%
Model No. Output Tol. R&N Effi.
ENP-360-12 13.8V, 0~26A ±1% 150mV 91%
ENP-360-24 27.6V, 0~13A ±1% 150mV 93%
ENP-360-48 55.2V, 0~6.5A ±1% 350mV 94%
Model No. Output Tol. R&N Effi.
ESP-240-13.5 13.5V, 0~16A ±2% 120mV 81%
ESP-240-27 27V, 0~8A ±1% 150mV 84%
ESP-240-54 54V, 0~4A ±1% 400mV 85%
Charger
108~360W Desktop Power Supply
Features for ESP Series Features for ENP Series
AC input range selectable by switch
Fanless design, cooling by free air convection (ESP-120)
Forced air cooling by built-in DC fan (ESP-240)
• Protections:
Short circuit / Overload / Over voltage / Over temperature
3 color LED loading indicator
2 years warranty
Universal AC input / Full range
Built-in active PFC function
No load power consumption <0.15W
Energy efficiency Level V
I
Comply with EISA 2007/DoE, NRCan, EU ErP and CoC Version 5
(EISA 2007/DoE, NRCan, EU ErP for ENP-360)
125% peak load capability
Fanless design, cooling by free air convection
Protections: Short circuit / Overload / Over voltage / Over temp.
3 years warranty
General Specification (Please refer to www.meanwell.com for detail spec.)
Order No. ESP-120 ESP-240 ENP-120 ENP-180 ENP-240 ENP-360
AC input voltage range 88~132VAC / 176~264VAC selectable by switch 90~264VAC; 127 ~ 370VDC
AC inrush current (max.) Cold start, 40A at 230VAC
Cold start,
65A at 230VAC
Cold start,
70A at 230VAC
Cold start,
75A at 230VAC
Cold start,
60A at 230VAC
DC adjustment range 13.5V: 12~15V, 27V: 24~30V, 54V: 48~56V 12V: 11.5~15V, 24V: 23.5~30V, 48V: 47.5~58.8V
Overload protection 105%~135% fold back current limiting, auto-recovery 110~125% constant current limiting, auto-recovery
Over voltage protection
115%~135% constant voltage limiting,
auto-recovery
110~130% shut down and latch off o/p voltage,
re-power on to recover
Over temp. protection Shut down o/p voltage, auto-recovery after temperature goes down
Withstand voltage I/P-O/P: 3kVAC, I/P-FG:1.5kVAC, O/P-FG: 0.5kVAC I/P-O/P:3KVAC, I/P-FG:2KVAC, O/P-FG:0.5KVAC
Working temperature -10~+60°C (refer to output derating curve)
-30~+70°C (refer to output derating curve)
Safety standards CSA 60950-1 approved UL60950-1 approved
EMC standards EN55032 class B, EN61000-3-2,-3, EN61000-4-2,3,4 EN55032 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Dimension (LxWxH)(mm) 150x 140x 75 192x 178x 45.5