MEAN WELL RPS-60-3.3 [89/112] Harsh environment

MEAN WELL EPS-45-48-C [89/112] Harsh environment
A
Blank
INPUT OUTPUT
240W / 320W / 480W ONLY
Standard
Optional
(Contact MW
for details)
HEP-
600
HEP-
240/320/480
86
Model No. Output Tol. R&N Effi.
HEP-240-12 A 12V, 0~16.0A ±2.5% 150mV 90.0%
HEP-240-15 A 15V, 0~15.0A ±2.0% 150mV 90.0%
HEP-240-24 A 24V, 0~10.0A ±1.0% 150mV 92.5%
HEP-240-36 A 36V, 0~6.70A ±1.0% 250mV 92.5%
HEP-240-48 A 48V, 0~5.00A ±1.0% 250mV 93.0%
HEP-240-54 A 54V, 0~4.45A ±1.0% 350mV 93.5%
= A or Blank, A: standard model(IP65), Blank: optional model(IP68)
Model No. Output Tol. R&N Effi.
HEP-320-12 A 12V, 0~22.0A ±3.0% 150mV 91.0%
HEP-320-15 A 15V, 0~19.0A ±2.0% 150mV 92.5%
HEP-320-24 A 24V, 0~13.34A ±1.0% 150mV 94.0%
HEP-320-36 A 36V, 0~8.90A ±1.0% 250mV 94.0%
HEP-320-48 A 48V, 0~6.70A ±1.0% 250mV 94.5%
HEP-320-54 A 54V, 0~5.95A ±1.0% 350mV 95.0%
= A or Blank, A: standard model(IP65), Blank: optional model(IP68)
240~600W Single Output
Features
General Specification (Please refer to www.meanwell.com for detail spec.)
Model No. HEP-240 HEP-320 HEP-480 HEP-600
AC input voltage range 90~305VAC; 127~431VDC
AC inrush current (max.) Cold start, 75A at 230VAC Cold start, 70A at 230VAC Cold start, 35A at 230VAC Cold start, 70A at 230VAC
DC adjustment range
Vo: -6%~+6% by potentiometer (HEP-240 A-Type only)
-10%~+10% by potentiometer (HEP-320 A-Type only)
Io: to 50%~100% of rated output current by
potentiometer (A-Type only)
Vo: -15%~+5% by potentiometer
Io: to 50%~100% of rated output current by potentiometer
Overload protection 105%~125% hiccup mode, auto-recovery 105%~125% constant current limiting, auto-recovery
Over voltage protection 108%~135% rated output voltage
Setup, rise, hold up time 500ms, 80ms, 15ms at full load and 230VAC 500ms, 80ms, 16ms 500ms, 80ms, 15ms
Withstand voltage I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 1.5kVAC
Working temperature -55~+70°C (refer to output derating curve) -55~+65°C -40~+70°C
Safety standards
UL60950-1 approved ; Design refer to TUV EN60950-1 UL60950-1, TUV EN60950-1 approved
EMC standards EN55032 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Connection
Input
UL rated, SJTW 18AWGx3C (30cm) UL rated, SJOW 17AWGx3C (30cm)
3+7P / 11mm pitch
terminal block with cover
Output SJTW 14AWGx2C (30cm) SJOW 17AWGx2C+17AWGx2C
Dimension (LxWxH)(mm) 244.2x 68x 38.8 252x 90x 43.8 262x 125x 43.8 280x 144x 48.5
• Universal AC input 90~305VAC
• Built-in active PFC function
No load power consumption <0.5W at remote OFF(HEP-600)
• High efficiency up to 96%
• Fanless design
, cooling by free air convection
• Ultra-wide operating temperature
• Meet 6kV surge immunity level (HEP-240/320)
• Withstand 10G vibration test
• Operating altitude up to 5000 meters
• Protections: Short circuit / Overload / Over voltage /
Over temperature
• Multiple models for choice (HEP-240/320/480):
A-Type:
IP65 rated, Vo and Io can be adjusted through
internal potentiometer
Blank-Type(option): IP68 rated, Vo and Io fixed
• Suitable for general industrial applications at high/low
temperature, high dust, high moisture, high vibration,
high salt or outdoor environment
• 6 years warranty
HEP-240 Series
HEP-600 Series
HEP-480 Series
HEP-320 Series
Harsh Environment
Model No. Output Tol. R&N Effi.
HEP-600-12 12V, 0~40A ±3.0% 150mV 93.0%
HEP-600-15 15V, 0~36A ±2.0% 150mV 94.0%
HEP-600-20 20V, 0~28A ±1.5% 150mV 95.0%
HEP-600-24 24V, 0~25A ±1.0% 150mV 95.0%
HEP-600-30 30V, 0~20A ±1.0% 200mV 95.5%
HEP-600-36 36V, 0~16.7A ±1.0% 250mV 95.5%
HEP-600-42 42V, 0~14.3A ±1.0% 250mV 96.0%
HEP-600-48 48V, 0~12.5A ±1.0% 250mV 96.0%
HEP-600-54 54V, 0~11.2A ±1.0% 350mV 96.0%
Model No. Output Tol. R&N Effi.
HEP-480-24 A 24V, 0~20A ±1.0% 200mV 94.0%
HEP-480-36 A 36V, 0~13.3A ±1.0% 250mV 95.0%
HEP-480-48 A 48V, 0~10A ±1.0% 250mV 94.5%
HEP-480-54 A 54V, 0~8.9A ±1.0% 350mV 95.0%
= A or Blank, A: standard model(IP65), Blank: optional model(IP68)
NEW

Содержание

Скачать