MEAN WELL RPS-60-3.3 [76/112] Charger

MEAN WELL MPT-65A [76/112] Charger
73
Model No. Output Tol. R&N Effi.
ESC-120-13.5 13.5V, 0~8A ±2% 120mV 81%
ESC-120-27 27V, 0~4A ±1% 150mV 83%
ESC-120-54 54V, 0~2A ±1% 400mV 84%
Model No. Output Tol. R&N Effi.
ENC-120-12 14.4V, 0~8A ±1% 150mV 89%
ENC-120-24 28.8V, 0~4A ±1% 150mV 90%
ENC-120-48 57.6V, 0~2A ±1% 350mV 90.5%
Model No. Output Tol. R&N Effi.
ENC-180-12 14.4V, 0~12A ±1% 150mV 91%
ENC-180-24 28.8V, 0~6A ±1% 150mV 92%
ENC-180-48 57.6V, 0~3A ±1% 350mV 93%
Model No. Output Tol. R&N Effi.
ENC-240-12 14.4V, 0~16A ±1% 150mV 91%
ENC-240-24 28.8V, 0~8A ±1% 150mV 92%
ENC-240-48 57.6V, 0~4A ±1% 350mV 93%
Model No. Output Tol. R&N Effi.
ENC-360-12 14.4V, 0~24A ±1% 150mV 91%
ENC-360-24 28.8V, 0~12A ±1% 150mV 93%
ENC-360-48 57.6V, 0~6A ±1% 350mV 94%
Model No. Output Tol. R&N Effi.
ESC-240-13.5 13.5V, 0~16A ±2% 120mV 81%
ESC-240-27 27V, 0~8A ±1% 150mV 84%
ESC-240-54 54V, 0~4A ±1% 400mV 85%
Charger
108~360W Desktop Charger
Features for ESC Series
Features for ENC Series
Desktop charger for lead-acid batteries
AC input range selectable by switch
Fanless design, cooling by free air convection (ESC-120)
Forced air cooling by built-in DC fan (ESC-240)
Protections: Short circuit / Overload / Over voltage / Over temp.
Battery under voltage / over voltage and reverse polarity protection
3 color LED loading indicator
2 years warranty
Desktop charger for lead-acid batteries and Li-ion batteries
Universal AC input / Full range
Built-in active PFC function
Built-in 3 stage charging curve, curve programming option available
Fanless design, cooling by free air convection
Protections: Short circuit / Over voltage / Over temperature
Battery under voltage / over voltage and reverse polarity protection
Built-in temperature compensation function
3 years warranty
General Specification (Please refer to www.meanwell.com for detail spec.)
Order No. ESC-120 ESC-240 ENC-120 ENC-180 ENC-240 ENC-360
AC input voltage range 88~132VAC / 176~264VAC selectable by switch 90~264VAC; 127 ~ 370VDC
AC inrush current (max.) Cold start, 40A at 230VAC
Cold start,
65A at 230VAC
Cold start,
70A at 230VAC
Cold start,
75A at 230VAC
Cold start,
60A at 230VAC
DC adjustment range 13.5V: 12~15V, 27V: 24~30V, 54V: 48~56V NA
Overload protection 105%~135% fold back current limiting, auto-recovery 110 ~ 125% constant current limiting, auto-recovery
Over voltage protection
115%~135% constant voltage limiting,
auto-recovery
110 ~ 130% shut down and latch off o/p voltage,
re-power on to recover.
Over temp. protection Shut down o/p voltage, auto-recovery after temperature goes down
Withstand voltage I/P-O/P: 3kVAC, I/P-FG:1.5kVAC, O/P-FG: 0.5kVAV I/P-O/P:3KVAC, I/P-FG:2KVAC, O/P-FG:0.5KVAC
Working temperature -10~+60°C (refer to output derating curve)
-30~+70°C (refer to output derating curve)
Safety standards CSA 61010-1 approved UL60950-1 approved
EMC standards EN55032 class B, EN61000-3-2,-3, EN61000-4-2,3,4 EN55032 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Dimension (LxWxH)(mm) 150x 140x 75 192x 178x 45.5
ESC-120 ESC-240 ENC-120 / 180 / 240 / 360
ESC-120 Series
ENC-120 Series
ENC-180 Series
ENC-240 Series
ENC-360 Series
ESC-240 Series
N
E
W
NEW
N
E
W
NEW

Содержание

Скачать