MEAN WELL RPS-65-48 [2/4] W single output medical type

MEAN WELL RPS-65-48 [2/4] W single output medical type
VOLTAGE TOLERANCE
Note.3
I/P-O/P: 4KVAC
VOLTAGE ADJ.RANGE
3.8~4.46V 5.75~6.75V 8.62~11.3V 13.8~16.2V 17.25~20.25V 27.6~32.4V 55.2~64.8V
SPECIFICATION
ORDER NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
Note.2
OUTPUT
VOLTAGE RANGE
Note.
4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
Note.
5
SAFETY STANDARDS
SAFETY &
EMC
(Note. 6)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
RPS 65 3 3--.
3.3V
80mVp-p
LINE REGULATION
LOAD REGULATION
±0.5%
±2.0%
80 ~ 264VAC
47 ~ 63Hz
80%
1.5A / 115VAC 1A / 230VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
959.1Khrs min.
-30 ~ +70 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
76.2*50.8*24mm (L*W*H)or 3" * 2" *0.945" inch
0.11Kg; 120pcs/14.2Kg/0.97CUFT
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2 medical level, criteria A
OVERLOAD
OVER VOLTAGE
115 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
10A
0 ~ 11A
33W
Protection type : Shut down o/p voltage, re-power on to recover
ANSI/AAMI ES60601-1 TUV EN60601-1 EС60601-1 approved,, I
Compliance to EN55011(CISPR11) class B, EN61000-3-2,3
SETUP, RISE TIME
HOLD UP TIME (Typ.)
500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load
30ms / 230VAC 12ms / 115VAC at full load
EMC IMMUNITY
EMC EMISSION
±0.03% / (0 ~ 50 )
℃℃
ISOLATION LEVEL
Primary-Secondary: 2xMOPP
PEAK LOAD(10sec.)
36 3W.
2.9~3.6V
±2.0%
Touch current< 100 A/264VAC
RPS 65--5
5V
80mVp-p
±0.5%
±2.0%
84%
10A
0 ~ 11A
50W
55W
47 55.~.V
±2.0%
RPS 65--.75
7.5V
80mVp-p
±0.5%
±2.0%
85%
0 ~ 8.8A
60W
66W
7.12~8.3V
±2.0%
RPS 65--12
12V
120mVp-p
±0.5%
±2.0%
88%
8A
0 ~ 5.96A
11.4~13.2V
±2.0%
RPS 65--15
15V
150mVp-p
±0.5%
±1.0%
89%
5.42A
0 ~ 4.77A
13.5~16.5V
±1.0%
RPS 65--24
24V
240mVp-p
±0.5%
±1.0%
90%
2.71A
0 ~ 2.98A
22.8~27.6V
±1.0%
RPS 65--48
48V
300mVp-p
±0.5%
±1.0%
91%
1.36A
0 ~ 1.49A
45.6~52.8V
±1.0%
4.34A
65W
71.5W
65.1W
71.6W
65W
71.5W
65.3W
71.5W
65W Single Output Medical Type
RPS-65 series
СOLD STAR 30A/115VAC 50A/230VAC
File Name: -SPEC 2015-11-04RPS 65-
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. Touch current was measured from primary input to DC output.
6.
The ambient temperature derating of 5 /1000m is needed for operating altitude greater than 2000m (6500ft).
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that
it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
MIL-HDBK-217(25 )