Daikin FXMQ80MVE [4/254] Troubleshooting op central remote controller 81

Daikin FXM100LVE [4/254] Troubleshooting op central remote controller 81
Si38-606
Table of Contents iii
2.17 E6 Standard Compressor Motor Overcurrent/Lock.............................137
2.18 E7 Malfunction of Outdoor Unit Fan Motor..........................................138
2.19 E9” Outdoor Unit: Malfunction of Moving Part of Electronic Expansion
Valve (Y1E, Y2E) .................................................................................140
2.20 F3” Outdoor Unit: Abnormal Discharge Pipe Temperature ..................142
2.21 F6 Refrigerant Overcharged ...............................................................143
2.22 H7 Abnormal Outdoor Fan Motor Signal .............................................144
2.23 H9” Outdoor Unit: Malfunction of Thermistor for Outdoor Air (R1T).....145
2.24 J2 Current Sensor Malfunction...........................................................146
2.25 J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R31 or 32T) .........................................................................................147
2.26 J5” Outdoor Unit: Malfunction of Thermistor (R2T) for Suction Pipe ...148
2.27 J6” Outdoor Unit: Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger ..............................................................149
2.28 J9Malfunction of Receiver Gas Pipe Thermistor (R5T).....................150
2.29 JA” Outdoor Unit: Malfunction of High Pressure Sensor......................151
2.30 JC” Outdoor Unit: Malfunction of Low Pressure Sensor.......................152
2.31 L4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise.................................................................................153
2.32 L5” Outdoor Unit: Inverter Compressor Abnormal ...............................154
2.33 L8” Outdoor Unit: Inverter Current Abnormal.......................................155
2.34 L9” Outdoor Unit: Inverter Start up Error..............................................156
2.35 LC” Outdoor Unit: Malfunction of Transmission between Inverter
and Control PC Board ..........................................................................157
2.36 P1” Outdoor Unit: Inverter Over-Ripple Protection ...............................159
2.37 P4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise Sensor ....................................................................160
2.38 “PJ” Outdoor Unit: Faulty Field Setting after Replacing
Main PC Board or Faulty Combination of PC Board ............................161
2.39 UOLow Pressure Drop Due to Refrigerant Shortage or
Electronic Expansion Valve Failure......................................................162
2.40 U1 Reverse Phase, Open Phase.........................................................163
2.41 U2Power Supply Insufficient or Instantaneous Failure ......................164
2.42 U3 Check Operation not Executed......................................................166
2.43 U4 Malfunction of Transmission between Indoor Units.......................167
2.44 U5 Malfunction of Transmission between Remote Controller
and Indoor Unit.....................................................................................169
2.45 U7Malfunction of Transmission between Outdoor Units ....................170
2.46 U8 Malfunction of Transmission between MAIN and
SUB Remote Controllers ......................................................................172
2.47 U9Malfunction of Transmission between Indoor and
Outdoor Units in the Same System ......................................................173
2.48 UAExcessive Number of Indoor Units ................................................175
2.49 UCAddress Duplication of Centralized Remote Controller .................176
2.50 UE Malfunction of Transmission between Centralized Remote
Controller and Indoor Unit ....................................................................177
2.51 UFRefrigerant System not Set, Incompatible Wiring/Piping ...............179
2.52 UHMalfunction of System, Refrigerant System Address Undefined...180
3. Troubleshooting (OP: Central Remote Controller) ..............................181
3.1 M1 PC Board Defect ............................................................................181
3.2 M8Malfunction of Transmission between Optional Controllers
for Centralized Control .........................................................................182