Zkteco LPRC100 [3/8] Connecting the wiring terminal

Zkteco LPRC100 [3/8] Connecting the wiring terminal
3
Note:
1) If the external fill light is installed very close to the camera (less than 30cm), the light from the fill light will be
directly reflected to the lens by the reflective coating on the license plate, causing overexposure of the license
plate in the video image and thus affecting the final recognition result. 
2) The external fill light shall be installed 40 cm ~ 50 cm above from the ground. You can adjust the angle of the
fill light so that the illuminated area between the ground and the license plate is little exposed, and the license
plate appears clearer. Avoid direct light on the license plate to prevent overexposure. 
 
Normal Overexposed
Wiring terminal diagram
Port description:
Pin Description
Reset
Reboots the device under the constant power
supply.
Ethernet Interface
Standard Ethernet RJ45 socket, 10M/100M
adaptive
+12V
GND
12V DC Power input. Pay attention to the positive
and negative electrodes.
NC1
COM1
NO1
Relay output for connecting to the barrier gate.
3. Connecting the wiring terminal