- Applicable model rs485 fingerprint reader 1
- Installation guide 1
- Dimensions mm 2
- Installation 2
- Note not all the devices have the fingerprint cover the real product prevails 2
- Procedure to be followed before installation 2
- Remove both the screws 2
- Step 1 2
- Installation 3
- Method 1 mounting on the standard single gang junction box 3
- Step 2 3
- After installing the back plate attach the machine part in the same reverse manner as shown in previous page 4
- Before the device is fastened please stick the paper to the place where you want to install it then make holes and lay cables according to the mounting paper 4
- Drill fixing holes and dig mounting groove deep of 36mm 4
- If cables need to be laid from behind then it must be done before installing 4
- Install the device with the screws 4
- Instruction for the mounting paper 4
- Method 2 mounting inside the wall 4
- Place the mounting sticker to the place where device needs to be installed 4
- Step 1 4
- Step 2 4
- Step 3 step 4 4
- Step 5 4
- 12v gnd 485 485 5
- Connected as inbio pro reader with external 485 maximum 8 readers can be connected the reader requires a separate power supply 5
- Connection with a control panel 5
- Dip switch 5
- Profp is an innovative silk id reader it needs to be connected to a host machine so that fingerprint information can be transferred through rs485 5
- Reader wires nomenclature and dip switch 5
- Red 12v black gnd yellow 485 purple 485 black gnd 5
- Switch 5
- Wiring terminals 5
- Address address 6
- Communication if the 485 communication wire is longer than 100 meters it is needed to set the number 6 dip switch of the last reader to on state that is parallel a terminal resistance of 120 ohm between 485 and 485 6
- Dip switch setting with control panel 6
- Number 1 2 3 4 of the dip switch are used to set the address of rs485 5 is the reset switch and 6 is the terminal resistance 6
- Number 5 is the reset switch dial up and dial down the machine will restart and reset successfully 6
- Number 6 switch is used to set the terminal resistance in rs485 6
- The right side figure shows the address number setting 6
- Working principle 6
- 12v gnd 7
- Connection with a standalone access controller 7
- Gnd 485a 7
- When using profp with standalone access controller device please move the dial code 1 to the on position as shown above 7
- Safety precautions 8
- Verification proccess 8
Похожие устройства
- Zkteco FR1500-WP Руководство пользователя
- Zkteco G4L Техническое описание
- Zkteco G4L Руководство пользователя
- Zkteco Horus TL1 Руководство пользователя
- Zkteco Horus TL1 Техническое описание
- Zkteco KR500 Техническое описание
- Zkteco KR600 Техническое описание
- Zkteco KR702E Техническое описание
- Zkteco KR702M Техническое описание
- Zkteco MR1010 Руководство пользователя
- Zkteco MR1010 Техническое описание
- Zkteco MR1020 Руководство пользователя
- Zkteco MR1020 Техническое описание
- Zkteco ProFaceX Техническое описание
- Zkteco ProFaceX Руководство пользователя
- Zkteco RS100 Техническое описание
- Zkteco TD-Channel 95 Техническое описание
- Zkteco TDM95E Техническое описание
- Zkteco ZK-178H Техническое описание
- Zkteco ZK-178K Техническое описание