Daikin RXQ34PY1 [200/355] Rx y q38p 40p 42p 44p 46p 48p 50p 52p 54py1 rxyq238p 40p 42p 44p 46p 48p 50p 52p 54pyl

Daikin RXQ18PY1 [200/355] Rx y q38p 40p 42p 44p 46p 48p 50p 52p 54py1 rxyq238p 40p 42p 44p 46p 48p 50p 52p 54pyl
Appendix SiEN34-705
194 General Information
RX(Y)Q38P, 40P, 42P, 44P, 46P, 48P, 50P, 52P, 54PY1
RXYQ238P, 40P, 42P, 44P, 46P, 48P, 50P, 52P, 54PYL
C: 3D052262B
2 Wires Cable
(Transmisson line)
2 Wires Cable
(Transmisson line)
2 Wires Cable
(Transmisson line)
2 Wires Cable
(Transmisson line)
[UNIT 2] [UNIT 3]
[UNIT 1]
2 Wires Cable
(Transmisson line)
2 Wires Cable
(Transmisson line)
[UNIT 2] [UNIT 3]
[UNIT 1]
2 Wires Cable
(Transmisson line)
2 Wires Cable
(Transmisson line)
2 Wires Cable
(Power line)
2 Wires Cable
(Power line)
2 Wires Cable
(Power line)
2 Wires Cable
(Transmisson line)
2 Wires Cable
(Transmisson line)
2 Wires Cable
(Transmisson line)
2 Wires Cable
(Power line)
2 Wires Cable
(Power line)
2 Wires Cable
(Power line)
Switch
Switch
Switch
Switch
Fuse
Fuse
Switch
Fuse
Fuse
Fuse
Switch
Switch
Switch
Fuse
Switch
Fuse
Switch
Fuse
Switch
Fuse
Switch
Fuse
Fuse
Fuse
Main
Switch
Main
Switch
Main
Switch
Power supply
Power supply
Main
Switch
Power supply
OUTDOOR UNITS
OUTDOOR UNITS
When the power source is connected in
series between the units.
INDOOR UNITS
2 Wires Cable
(Power line)
2 Wires Cable
(Power line)
2 Wires Cable
(Power line)
2 Wires Cable
(Power line)
2 Wires Cable
(Power line)
INDOOR UNITS
Power supply
Notes
1) All wiring, components and materials to be procured on the site must
comply with the applicable local and national codes.
2) Use copper conductors only
3) As for details, see wiring diagram.
4) Install circuit breaker for safety.
5) All field wiring and components must be provided by licensed
electrician.
6) Unit shall be grounded in compliance with the applicable local and national codes.
7) Wiring shown are general points-of-connection guides only are not intended for or to include all details for or to specific
installation.
8) Be sure to install the switch and the fuse to the power line of each equipment.
9) Install the main switch that can interrupt all the power sources in an integrated manner because this system consists of
the equipment utilizing the multiple power sources.
10) The capacity of UNIT1 must be larger than UNIT2 when the power source is connected in series between the units.
11) If there exists the possibility of reversed phase, lose phase, momentary blackout or the power goes on and off while the
product is operating, attach a reversed phase protection circuit locally.
Running the product in reversed phase may break the compressor and other parts.
When the power source is supplied to each
outdoor unit individually.