Daikin RXYQ48PAYL [34/36] Installation box for adaptor pcb

Daikin RXYQ48PAYL [34/36] Installation box for adaptor pcb
kg/h
%
%
%
kW
mm
Net
Gross
(Note 8)
kg
Around Unit
OA (Note 9)
RA (Note 9)
mm
MODEL
Refrigerant
Power Supply
Airflow rate
m
3
/h
Static pressure
Pa
Airflow rate
m
3
/h
Static pressure Pa
Heat
exchange
mode
Bypass
mode
Airflow rate
m
3
/h
Static pressure
Pa
kW
Ultra-high
High
dB(A)
Low
Ultra-high
High
dB(A)
Low
Ultra-high
High W
Low
Ultra-high
High W
Low
Airflow Rate & Static
Pressure (Note 7)
Ultra-high
High
Low
Heat
exchange
mode
Bypass
mode
Fan Type
Motor Output
Sound Level (Note 5)
(220/230/240 V)
Humidification Capacity (Note 4)
Temp. Exchange
Efficiency
Ultra-high
High
Low
Enthalpy Exchange
Efficiency (Cooling)
Ultra-high
High
Low
Enthalpy Exchange
Efficiency (Heating)
Ultra-high
High
Low
Casing
Insulating Material
Heat Exchanging System
Heat Exchanger Element
Air Filter
DX-coil
Capacity
Cooling (Note 2)
Heating (Note 3)
Height
Width
Depth
Dimensions
Machine Weight
Unit Ambient Condition
Connectable outdoor units
Connection Duct Diameter
Power Consumption
6665
SPECIFICATIONS
Notes:
1. Cooling and heating capacities are based on the following conditions. Fan is based on High and Ultra-high.
When calculating the capacity as indoor units, use the following figures:
VKM50GAMV1/GV1: 3.5 kW, VKM80GAMV1/GV1: 5.6 kW, VKM100GAMV1/GV1: 7.0 kW
2. Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB
3. Indoor temperature: 20°C DB, Outdoor temperature: 7°C DB, 6°C WB
4. Humidifying capacity is based on the following conditions:
Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB
5. The operating sound measured at the point 1.5 m below the centre of the unit is converted to that measured
in an anechoic chambar built in accordance with the JIS C 1502 conditions. The actual operating sound
varies depending on the surrounding conditions (near running unit’s sound, reflected sound and so on) and is
normally higher than this value.
For operation in a quiet room, it is required to take measures to lower the sound.
For details, refer to the Engineering Data.
6. The noise level at the air discharge port is about 8–11 dB(A) or higher than the unit’s operating sound.
For operation in a quiet room, it is required to take measures to lower the sound.
7. Airflow rate can be changed over to Low mode or High mode.
8. In case of holding full water in humidifier.
9. OA: fresh air from outdoor. RA: return air from room.
10. Specifications, design and information here are subject to change without notice.
11. Power consumption and efficiency depend on the above value of airflow rate.
12. Temperature exchange efficiency is the mean value for Cooling and Heating. Efficiency is measured under
the following condition: Ratio of rated external static pressure outdoor to indoor is kept constant at 7 to 1.
13. In heating operation, freezing of the outdoor unit’s coil increases. Heating capability decreases and the
system goes into defrost operation. During defrost operation, the fans of the unit continues driving (factory
setting). The purpose of this is to maintain the amount of ventilation and humidifying.
14. When connecting with a VRV system heat recovery outdoor unit and bringing the RA (exhaust gas intake)
of this unit directly in from the ceiling, connect to a BS unit identical to the VRV indoor unit (master unit),
and use group-linked operation. (See the Engineering Data for details.)
15. When connecting the indoor unit directly to the duct, always use the same system on the indoor unit as
with the outdoor unit, perform group-linked operation, and make the direct duct connection settings from
the remote controller. (Mode No. “17 (27)” – First code No. “5” – Second code No. “6”.) Also, do not
connect to the outlet side of the indoor unit. Depending on the fan strength and static pressure, the unit
might back up.
Feed clean water (city water, tap water or equivalent). Dirty water may clog the
valve or cause dirt deposits in the water container, resulting in poor humidifier performance. (Never use
any cooling tower water and heating-purpose water.)
Also, if the supply water is hard water, use a water softener because of short life.
* Life of humidifying element is about 3 years (4,000 hours) under the supply water conditions of
hardness: 150 mg/l. (Life of humidifying element is about 1 year
(1,500 hours) under the supply water conditions of hardness: 400 mg/l.)
Annual operating hours: 10 hours/day x 26 days/month x 5 months = 1,300 hours
VKM50GAMV1 VKM80GAMV1 VKM100GAMV1
VKM50GAV1 VKM80GAV1 VKM100GAV1
R-410A
1-phase, 220–240 V, 50 Hz
500 750 950
160 140 110
500 750 950
120 90 70
440 640 820
100 70 60
560
490
420
560
490
420
620
560
470
620
560
470
670
570
480
670
570
480
Sirocco Fan
0.280 x 2 0.280 x 2 0.280 x 2
37/37.5/38
35/35.5/36
32/33/34
37/37.5/38
35/35.5/36
32/33/34
38.5/39/40
36/37/37.5
33/34/35.5
38.5/39/40
36/37/37.5
33/34/35.5
39/39.5/40
37/37.5/38
34/34.5/35.5
39/39.5/40
37/37.5/38
34/34.5/35.5
2.7 4.0 5.4
76 78 74
76 78 74
77.5 79 76.5
64 66 62
64 66 62
67 68 66
67 71 65
67 71 65
69 73 69
Galvanised Steel Plate
Self-Extinguishable Urethane Foam
Air to Air Cross Flow Tot al Heat (Sensible + Latent Heat) Exchange
Specially Processed Nonflammable Paper
Multidirectional Fibrous Fleece
0°C–40°C DB, 80%RH or less
-15°C–40°C DB, 80%RH or less
0°C–40°C DB, 80%RH or less
s
387 387 387
1,764 1,764 1,764
832 1,214 1,214
500
180
500
150
440
110
560
490
420
560
490
420
0.280 x 2
38/38.5/39
36/36.5/37
33.5/34.5/35.5
38/38.5/39
36/36.5/37
33.5/34.5/35.5
76
76
77.5
64
64
67
67
67
69
750
170
750
120
640
80
620
560
470
620
560
470
0.280 x 2
40/41/41.5
37.5/38/39
34.5/36/37
40/41/41.5
37.5/38/39
34.5/36/37
78
78
79
66
66
68
71
71
73
950
150
950
100
820
70
670
570
480
670
570
480
0.280 x 2
40/40.5/41
38/38.5/39
35/36/36.5
40/40.5/41
38/38.5/39
35/36/36.5
74
74
76.5
62
62
66
65
65
69
2.8
3.2
387
1,764
832
96
2.8
3.2
4.5
5.0
5.6
6.4
4.5
5.0
387
1,764
1,214
109
5.6
6.4
387
1,764
1,214
114
102
107
120
129
125
134
RX(Y)Q5–54PAY1, RX(Y)Q16–50PAHY1
ø200 ø250 ø200 ø250
DIMENSIONS
4-14 x 40 oval hole
Hanger bracket
Supply air to room
SA
Return air from room
RA
(For humidifier)*
1
Maintenance cover
(Natural evaporative type)*
1
Humidifier
Solenoid valve*
1
EA
(Outdoor air)
Fresh air from outdoors
Exhaust air to outdoors
OA
Control box
Maintenance Cover
More than 600
hatch
Inspection
hatch
Inspection
the air filters, fans (and humidifier)
Maintenance space for the heat exchanger elements
140 (In case of 600 inspection hatch)
360 (In case of 450 inspection hatch)
High efficiency filter (option)
Liquid pipe connection
Air filters
(PT3/4 male screw)
(ø12.7)
(ø6.4)
connection
Gas pipe
Heat exchanger
elements
Drain outlet
(ø6.4C1220T)
Feed water connection port *
1
of the heat exchanger elements.
Note *1. VKM50/80/100GAMV1 only.
The high efficiency filter (option) can be attached to the SA surface*
( 450 or 600) at the service side of filters and elements.
Be sure to provide two inspection hatch.*
The specification subject to change without notice.*
VKM50/80/100GA(M)V1
210
B
42
Supply air fan
160
250150
153
C
Damper plate
210
G
K
1688
387
235
60
10
I
20
153
F
Feed water tank*
1
D
130
E
160
144
A
28
102
Direct expansion coil
34
H
J
322
20
1764
515
Exhaust air fan
94
VKM50GA(M)V1
VKM80/100GA(M)V1
832A 1,214
248B 439
431C 622
164D 183
420E 592
248F 439
878G 1,262
137H 89
137I 89
ø196J ø246
ø250K ø263
For wiring
Central remote controller
Remote controller
Wiring adaptor for electrical
appendices
Type
(indoor unit of VRV)
Installation box for adaptor PCB
Unified ON/OFF controller
Schedule timer
For humidifier running ON signal output
For heater control kit
BRC1E61/BRC1C62/BRC1D61
*1
DCS302CA61
Residential central remote controller
DCS303A51
*2
DCS301BA61
DST301BA61
KRP2A61
KRP50-2
BRP4A50
FXCQ-M
FXKQ-MA
FXFQ-P
FXLQ-MA
FXNQ-MA
KRP1B61
KRP1C63
KRP1B61
Notes 2, 3
KRP1B96
Notes 2, 3
KRP1H98
FXZQ-M
KRP1BA57
Note 4, 6
KRP1BA101
Item
Type
Controlling device
PC Board Adaptor
Centralised
controlling
device
Notes: 1.
2.
3.
4.
5.
Installation box is necessary for each adaptor marked .
Up to 2 adaptors can be fixed for each installation box.
Only one installation box can be installed for each indoor unit.
Up to 2 installation boxes can be installed for each indoor unit.
Installation box is necessary for second adaptor.
FXUQ-MA
KRP1BA97
KRP1B61
FXDQ-PB
FXDQ-NB
Notes 4, 6
KRP1BA101
KRP1B56
6.
7.
Installation box is necessary for each adaptor.
*1 Necessary when operating a Heat Reclaim Ventilator (VKM) independently. When operating interlocked
with other air conditioners, use the remote controllers of the air conditioners.
*2 For residential use only. When connected with a Heat Reclaim Ventilator (VKM), you can only switch
the power ON/OFF. Cannot be used with other centralised control equipment.
VKM50/80/100GA(M)V1
Silencer
Air suction/
Discharge grille
High efficiency filter
Flexible duct (1 m)
Flexible duct (2 m)
VKM50GA(M)V1 VKM80GA(M)V1 VKM100GA(M)V1
KDDM24B100
250 mm
K-DGL200B
K-DGL250B
200 250
KAF242H80M KAF242H100M
Air filter for replacement
KAF241G80M KAF241G100M
K-FDS201D K-FDS251D
K-FDS202D K-FDS252D
White
Item
Type
Additional function
OPTIONS
Air Treatment Equipment Lineup
FXHQ-MA FXAQ-P
FXMQ-P
Notes 2, 3
KRP4A96
KRP1BA54
Notes 2, 3
KRP4AA93
Note 3
KRP1CA93
FXMQ-MA
KRP1B61
KRP1C64
Nominal pipe diameter
Nominal pipe diameter
mm
mm