Daikin RXQ44PHY1 [4/394] Troubleshooting by indication on the remote controller 98

Daikin RXQ44PHY1 [4/394] Troubleshooting by indication on the remote controller 98
Si34-704
Table of Contents iii
3. Troubleshooting by Indication on the Remote Controller ....................198
3.1 A0” Indoor Unit: Error of External Protection Device ...........................198
3.2 A1” Indoor Unit: PC Board Defect.........................................................199
3.3 A3” Indoor Unit: Malfunction of Drain Level Control System (S1L) ......200
3.4 A6” Indoor Unit: Fan Motor (M1F) Lock, Overload...............................202
3.5 A7” Indoor Unit: Malfunction of Swing Flap Motor (M1S) .....................203
3.6 A9Electronic Expansion Valve Malfunction / Dust Clogging ..............205
A9” Indoor Unit: Malfunction of Electronic Expansion Valve Coil.........207
3.7 AF” Indoor Unit: Drain Level above Limit..............................................209
3.8 AJ” Indoor Unit: Malfunction of Capacity Determination Device ..........210
3.9 C4” Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger....................................................................................211
3.10 C5” Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes..........212
3.11 C9” Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air.........213
3.12 CAIndoor unit: Malfunction of Thermistor (R4T) for discharge Air......214
3.13 CJ” Indoor Unit: Malfunction of Thermostat Sensor in
Remote Controller ................................................................................215
3.14 E1” Outdoor Unit: PC Board Defect ......................................................216
3.15 E3” Outdoor Unit: Actuation of High Pressure Switch ..........................217
3.16 E4” Outdoor Unit: Actuation of Low Pressure Sensor..........................219
3.17 E5 Outdoor Unit: Inverter Compressor Motor Lock.............................221
3.18 E6 Outdoor Unit: STD Compressor Motor Overcurrent/Lock..............223
3.19 E7 Outdoor Unit: Malfunction of Outdoor Unit Fan Motor ...................224
3.20 E9” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y2E)...............................................227
3.21 F3” Outdoor Unit: Abnormal Discharge Pipe Temperature ..................229
3.22 F6 Outdoor Unit: Refrigerant Overcharged.........................................231
3.23 H7 Outdoor Unit: Abnormal Outdoor Fan Motor Signal.......................232
3.24 H9” Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air.....234
3.25 J2 Outdoor Unit: Current Sensor Malfunction ....................................235
3.26 J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R3, R31, 32T)......................................................................................236
3.27 J5” Outdoor Unit: Malfunction of Thermistor (R2T), (R7T) for
Suction Pipe .........................................................................................238
3.28 J6” Outdoor Unit: Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger ..............................................................239
3.29 J7” Outdoor Unit: Malfunction of Liquid Pipe Thermistor 1 (R6T)........240
3.30 J9” Outdoor Unit: Malfunction of Subcooling Heat
Exchanger Gas Pipe Thermistor (R5T) ................................................242
3.31 JA” Outdoor Unit: Malfunction of High Pressure Sensor......................243
3.32 JC” Outdoor Unit: Malfunction of Low Pressure Sensor.......................245
3.33 L1” Outdoor Unit: Defective Inverter PCB.............................................247
3.34 L4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise.................................................................................248
3.35 L5” Outdoor Unit: Momentary Overcurrent of Inverter Compressor.....250
3.36 L8” Outdoor Unit: Momentary Overcurrent of Inverter Compressor.....252
3.37 L9” Outdoor Unit: Inverter Compressor Starting Failure ......................254
3.38 LC” Outdoor Unit: Malfunction of Transmission between Inverter
and Control PC Board ..........................................................................257
3.39 P1” Outdoor Unit: Inverter Over-Ripple Protection ...............................260
3.40 P4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise Sensor ....................................................................261