Planet IFT-802 [5/18] Product specification
![Planet IFT-802 [5/18] Product specification](/views2/1071814/page5/bg5.png)
▫ DIN-Rail or wall mountable
▫ DIP-switches to set the operation mode and Link- Lost-Forwarding function.
Industrial Conformance:
▫ 12~48V DC, redundant power with polarity reverse protect function and connective
removable terminal block for master and slave power
▫ 0 to 60 Degree C operation temperature
▫ IP-30 Aluminum case
▫ EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE
EN6100-4-5 and CE EN6100-4-6
▫ Stability testing with IEC60068-2-32(Free fall), IEC60068-2-27(Shock) and
IEC60068-2-6(Vibration)
1.4 Product Specification
Model IFT-802
Standard IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX / 100BASE-FX
IEEE 802.3x Flow Control and Back pressure
10/100Mbps TP CAT-3/5 (10/100Mbps) Twisted Pair cable Auto MDI/MDI-X and Auto-Negotiation
Function Support
Fiber Connector Multi-Mode SC connector
Architecture Store and forward
Fiber Parameters Fiber Core: Multi-Mode (62.5/125µm, 50/125µm). Wavelength: 1310nm
Fiber Distance: Multi-Mode Fiber, up to 2Km
Link Lost Forward TX to Fiber: If TX port link down, the media converter will force Fiber port to link down
Fiber to TX: If Fiber port link down, the media converter will force TX port to link down.
DIP Switch DIP Switch 1:
ON: Enables Port Alarm
OFF: Disables Port Alarm
DIP Switch 2:
ON: Enables LLF (Link Lose Forwarding)
OFF: Disables LLF (Link Lose Forwarding)
DIP Switch 3:
ON: 100Base-FX Half-mode
OFF: 100Base-FX Full-mode
DIP Switch 4:
ON: 100Base-TX Full-duplex mode
OFF: Auto-Negotiation
LED Power (Green), Power1 (Green), Power2 (Green), Fault (Orange)
Fiber: Link/Activity (Green)
Half/Full Duplex (Orange)
Содержание
- Base fx media converter 1
- Ift 802 1
- Industrial 10 100base tx to 1
- User s manual 1
- Ce mark warning 2
- Disclaimer 2
- Fcc warning 2
- Revision 2
- Trademarks 2
- Weee warning 2
- Table of contents 3
- How to use this manual 4
- Introduction 4
- Packet contents 4
- Product feature 4
- 0 to 60 degree c operation temperature 5
- 100mbps tp 5
- 12 48v dc redundant power with polarity reverse protect function and connective 5
- Architecture 5
- Din rail or wall mountable 5
- Dip switch 5
- Dip switches to set the operation mode and link lost forwarding function 5
- Emi complies with fcc class a ce en6100 4 2 ce en6100 4 3 ce en6100 4 4 ce 5
- En6100 4 5 and ce en6100 4 6 5
- Fiber connector 5
- Fiber parameters 5
- Iec60068 2 6 vibration 5
- Industrial conformance 5
- Ip 30 aluminum case 5
- Link lost forward 5
- Product specification 5
- Removable terminal block for master and slave power 5
- Stability testing with iec60068 2 32 free fall iec60068 2 27 shock and 5
- Standard 5
- Dimension w x d x h 6
- Emission 6
- Installation 6
- Operating environment 6
- Power consumption 6
- Power supply 6
- Stability testing 6
- Storage environment 6
- Installation 7
- Product description 7
- Product overview 7
- Switch front panel 7
- 100 utp 8
- Fdx fiber 8
- Fdx utp 8
- Led indications 8
- Led status meaning 8
- Lnk act fiber 8
- Lnk act utp 8
- Power 1 8
- Power 2 8
- Real time information of system and optional status the following table provides description of the led 8
- Status and their meanings for the industrial media converter 8
- There are 9 diagnostic leds located on the front panel of industrial media converter they provide 8
- Converter bottom panel 9
- Dip switch 9
- Notice 9
- Status 9
- Wiring the fault alarm contact 10
- Wiring the power inputs 10
- Din rail mounting 11
- Fault alarm contact 11
- Mounting installation 11
- V dc buzzer 24v battery 11
- Wall mount plate mounting 12
- Hardware installation 14
- Installation steps 14
- Notice 15
- Diagnosing led indicators 16
- Faulty or loose cables 16
- Improper network topologies 16
- Incorrect connections 16
- Incorrect power input 16
- Non standard cables 16
- Troubleshooting 16
- Cabling 17
- A rj 45 cable pin assignment 18
- A switch s rj 45 pin assignments 18
- Appendix a networking connection 18
Похожие устройства
- Elna ELNAPRESS 320 Инструкция по эксплуатации
- Planet UMG-2000 Инструкция по эксплуатации
- Elna ELNAPRESS 520 Инструкция по эксплуатации
- Бастион СКАТ-1200А Инструкция по эксплуатации
- De Dietrich GTU 120 Инструкция по эксплуатации
- Бастион СКАТ-1200C Инструкция по эксплуатации
- HP CN684HE 301 №178XL Инструкция по эксплуатации
- De Dietrich GTU 1200 V Инструкция по эксплуатации
- Бастион СКАТ-1200Б Инструкция по эксплуатации
- Asus RT-N10 C1 Инструкция по эксплуатации
- De Dietrich GT 120 Инструкция по эксплуатации
- Rapoo 3300p Black Инструкция по эксплуатации
- Бастион СКАТ-1200Д Инструкция по эксплуатации
- Rapoo 3300p White Инструкция по эксплуатации
- De Dietrich GT 1200 Инструкция по эксплуатации
- Бастион СКАТ-1200М Инструкция по эксплуатации
- De Dietrich MS 24 Инструкция по эксплуатации
- Бастион СКАТ-1200И7 Инструкция по эксплуатации
- De Dietrich MS 24 MI Инструкция по эксплуатации
- Бастион СКАТ-1200 Инструкция по эксплуатации