03
2.2.3: (ST1000-G Evolution Load Range)
2.2.4: (ST1200-G Evolution Load Range)
1.Maximum continuous total DC output power should not exceed 850W.
2.Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not
exceed 150W.
3.Maximum current for +12V outputs shall be 70A(840W).
4.Maximum peak total DC output power should not exceed 950W.
5.Peak power and current loading shall be supported for a minimum of 12 second.
6.When +12V is load to 28A , -12V minimum load is 0.02A.
1.Maximum continuous total DC output power should not exceed 1000W.
2.Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not
exceed 150W.
3.Maximum current for +12V outputs shall be 83A(996W).
4.Maximum peak total DC output power should not exceed 1100W.
5.Peak power and current loading shall be supported for a minimum of 12 second.
6.When +12V is load to 28A , -12V minimum load is 0.02A.
1.Maximum continuous total DC output power should not exceed 1200W.
2.Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not
exceed 150W.
3.Maximum current for +12V outputs shall be 100A(1200W).
4.Maximum peak total DC output power should not exceed 1300W.
5.Peak power and current loading shall be supported for a minimum of 12 second.
6.When +12V is load to 28A , -12V minimum load is 0.02A.
Parameter Min. Max. Unit
+3.3V 0.3 25 Amps
+5V 0.3 25 Amps
+12V 0.1 83 Amps
-12V 0 0.3 Amps
+5VSB 0.1 3.5 Amps
Parameter Min. Max. Unit
+3.3V 0.3 25 Amps
+5V 0.3 25 Amps
+12V 0.1 100 Amps
-12V 0 0.3 Amps
+5VSB 0.1 3.5 Amps
04
2.3 Output Ripple
2.4 Overshoot
2.3.1 Ripple regulation
2.3.2 Definition
2.3.3 Ripple voltage test circuit
STRIDER GOLD EVOLUTION SERIES
Parameter Ripple&Noise Unit
+3.3V <50 mVp-p
+5V <50 mVp-p
+12V <120 mVp-p
-12V <120 mVp-p
+5VSB <50 mVp-p
The ripple voltage of the outputs shall be measured at the pins of the output connec-
tor when terminated in the load impedance specified in figure 1. Ripple and noise are
measured at the connectors with a 0.1uF ceramic capacitor and a 10uF electrolytic
capacitor to simulate system loading. Ripple shall be measured under any condition
of line voltage, output load, line frequency, operation temperature.
AC Hot
AC Neutral
Power Supply
V out
V return
10uF 0.1uF
Load
Scope
AC Ground
Any overshoot at turn on or turn off shall be less 10% of the norminal voltage value, all
outputs shall be within the regulation limit of section 2.0 before issuing the power
good signal of section 5.0 .