Icom IC-R9000L [65/72] Warning

Содержание

Похожие устройства

MAINTENAN 11 5 FUSE REPLACEMENT WARNING DISCONNECT the AC power cable from the receiver before performing any work on the receiver 1 AC POWER INPUT FUSE The IC R9000 has 3 fuses for receiver protection AC power input 2 A Regulator circuit 4 A 13 8 V output jack 0 5 A If the fuse blows or the receiver stops functioning source of the problem if possible and replace the fuse with a new rated fuse The AC power input fuse is held in the FUS Unscrew the FUSE holder using a philips he driver then replace the damaged fuse with a new r REPLACEMENT FUSE FGB 2 A FGMS 2 A for German 2 REGULATOR CIRCUIT FUSE The regulator circuit fuse is located under the RF A 1 Remove the top and bottom covers See Se p 61 for details 2 Open the shield case from the PA unit and un nector J2 as shown in the diagram 3 Unscrew 1 screw holding the RF A unit on ea total of 2 screws Lift up the RF A unit from side toward the front side as shown in the diagra 4 Replace the damaged regulator circuit fuse w rated one REPLACEMENT FUSE FGB 4 A 3 13 8 V DC OUTPUT JACK FUSE LOCATION UNDER THE BOTTOM COVER When an external connection via the DC OUTPUT or the ACC socket has a problem the fuse may b the fuse blows the receiver operates normally How the above jacks do not output 13 8 V DC 1 Remove the top and bottom covers See Se p 61 for details 2 Set the receiver upside down 3 Replace the damaged fuse with a new rated one The 13 8 V DC output fuse is located near MIX switch on the rear panel Refer to p 66 for detailed location REPLACEMENT FUSE FGB 0 5 A

Скачать