3 | Operation
User reference guide
28
EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596810-1 – 2019.10
INFORMATION
In case of weather dependency, an offset value can be modified.
3.4.10 External room thermostat control - About external room thermostat control
External room thermostat control means that you control the following:
▪ Room temperature on the external thermostat control
▪ Leaving water temperature on the user interface (Daikin)
To control the leaving water temperature, you can do the following:
You can… Location
Read out the desired leaving water temperature. Leaving water
temperature home pages
(main + additional)
Adjust the desired leaving water temperature.
Only change this if the desired room temperature
cannot be reached.
See also: "3.4.6 Room thermostat control - Using the leaving water temperature
home pages"[424]
3.4.11 External room thermostat control - Using external room thermostat control
To adjust the leaving water temperature (main)
1 Go to the main leaving water temperature home page (LWT main).
2 Press or to adjust. Example:
35°C 37°C
To adjust the leaving water temperature (additional)
1 Go to the additional leaving water temperature home page (LWT add).
2 Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
3.5 Domestic hot water control
NOTICE
Disinfection mode. Even if you turn OFF domestic hot water operation via the
DHWtank temperature home page (Tank), disinfection mode will remain active.
3.5.1 About domestic hot water control
Depending on the DHWtank mode (installer setting), you use a different domestic
hot water control:
▪ Reheat mode
▪ Scheduled mode
▪ Scheduled + reheat mode
Содержание
- Daikin altherma 3 r f p.1
- General information 6 p.2
- Energy saving tips 48 p.2
- User reference guide p.2
- Table of contents p.2
- Operation 11 p.2
- Installer settings tables to be filled in by installer 4 p.2
- Table of contents p.3
- Relocation 54 p.3
- Maintenance and service 49 p.3
- Glossary 56 p.3
- Disposal 55 p.3
- Troubleshooting 51 p.3
- Space heating cooling control p.4
- Quick wizard p.4
- Installer settings tables to be filled in by installer p.4
- Installer settings tables to be filled in by p.4
- Installer p.4
- Installer settings tables to be filled in by installer p.5
- Domestic hot water control a p.5
- Contact helpdesk number 6 p.5
- General information p.6
- General safety precautions p.6
- For the user p.6
- General information p.7
- About this document p.7
- About the documentation p.7
- General information p.8
- Meaning of warnings and symbols p.8
- General information p.9
- Produce domestic hot water p.10
- Heat up a space p.10
- General information p.10
- Depending on the system layout the system can p.10
- Cool down a space only with ekhvconv3 conversion kit installed p.10
- Components in a typical system layout p.10
- About the system p.10
- User interface overview p.11
- Operation p.11
- Buttons p.11
- Status icons p.12
- Operation p.12
- User permission level p.13
- Operation p.13
- Operation p.14
- Menu structure overview user settings p.14
- Using the menu structure p.15
- Using home pages p.15
- Operation p.15
- Basic usage p.15
- Turning on off controls p.16
- Operation p.16
- Space heating cooling control p.17
- Setting the space operation mode p.17
- Operation p.17
- About space heating cooling control p.17
- Operation p.18
- Operation p.19
- Determining which temperature control you are using p.19
- Operation p.20
- Room thermostat control about room thermostat control p.20
- Room thermostat control using the room temperature home pages p.21
- Operation p.21
- Operation p.22
- Operation p.23
- Room thermostat control using the leaving water temperature home pages p.24
- Operation p.24
- Operation p.25
- C 47 c p.25
- C 37 c p.25
- Operation p.26
- Leaving water temperature control about leaving water temperature control p.26
- C 47 c p.26
- C 37 c p.27
- According to a schedule p.27
- A schedule p.27
- Operation p.27
- Leaving water temperature control using leaving water temperature control not p.27
- Leaving water temperature control using leaving water temperature control according to p.27
- C 47 c p.27
- Operation p.28
- External room thermostat control using external room thermostat control p.28
- External room thermostat control about external room thermostat control p.28
- Domestic hot water control p.28
- C 47 c p.28
- C 37 c p.28
- About domestic hot water control p.28
- Reheat mode p.29
- Operation p.29
- Scheduled mode p.30
- Operation p.30
- Operation p.31
- Scheduled reheat mode p.31
- Using the dhw tank temperature home page p.32
- Operation p.32
- Using the dhw tank booster mode p.33
- Operation p.33
- Using quiet mode p.34
- Operation p.34
- Advanced usage p.34
- About changing the user permission level p.34
- Using holiday mode p.35
- Operation p.35
- Operation p.36
- Holiday p.36
- Operation p.37
- Reading out information p.38
- Operation p.38
- Operation p.39
- Configuring user profile and home pages p.39
- Configuring date time units of measurement contrast and backlight p.39
- Operation p.40
- Locking and unlocking buttons and functions p.40
- Using preset values p.41
- Preset values and schedules p.41
- Operation p.41
- Using and programming schedules p.42
- Operation p.42
- Schedules example p.43
- Operation p.43
- Predefined schedules room temperature leaving water temperature main p.44
- Predefined schedules leaving water temperature additional p.44
- Operation p.44
- Operation p.45
- What is a weather dependent curve p.45
- Weather dependent curve p.45
- Predefined schedules dhw tank temperature p.45
- Using weather dependent curves p.46
- Points curve p.46
- Operation p.46
- Operation p.47
- Energy saving tips p.48
- Overview maintenance and service p.49
- Maintenance and service p.49
- To find the contact helpdesk number p.50
- Maintenance and service p.50
- Troubleshooting p.51
- To check the warning history p.51
- To check the error history p.51
- Symptom heat pump failure p.52
- Troubleshooting p.52
- Symptom you are feeling too cold hot in your living room p.52
- Symptom the water at the tap is too cold p.52
- Troubleshooting p.53
- Symptom the system is making gurgling noises after commissioning p.53
- Relocation p.54
- Overview relocation p.54
- Notice p.55
- Disposal p.55
- Glossary p.56
Похожие устройства
-
Daikin EVLQ08CAV3Руководство по применению для установщика -
Daikin EVLQ08CAV3Справочное руководство для монтажника -
Daikin EVLQ08CAV3Общие правила техники безопасности -
Daikin EVLQ08CAV3Инструкция по монтажу -
Daikin EVLQ05CAV3Справочное руководство для монтажника -
Daikin EVLQ05CAV3Руководство по применению для установщика -
Daikin EVLQ05CAV3Общие правила техники безопасности -
Daikin EVLQ05CAV3Инструкция по монтажу -
Daikin EHYKOMB33AA3Справочное руководство для монтажника -
Daikin EHYKOMB33AA3Руководство по применению для установщика -
Daikin EHYKOMB33AA3Руководство по эксплуатации -
Daikin EHYKOMB33AA2Руководство по применению для установщика
Узнайте, как управлять температурой в помещениях и горячей водой с помощью внешнего термостата. Настройте параметры для достижения комфортного климата в вашем доме.