Daikin EHFH03S18DJ3V [5/60] Domestic hot water control a
1 | Installer settings: Tables to be filled in by installer
User reference guide
5
EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596810-1 – 2019.10
Setting Fill in…
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
Leaving water temperature: Delta T source [A.3.1.3]
Heating
Cooling
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type
1.3 Domestic hot water control [A.4]
Setting Fill in…
Type
Maximum setpoint
INFORMATION
There is a risk of space heating (or cooling) capacity shortage/comfort problem when
selecting [6‑0D]=0 ([A.4.1] Domestic hot water Type=Reheat only).
In case of frequent domestic hot water operation, frequent and long space heating
interruption will happen.
INFORMATION
When the DHW tank booster mode is active, the risk of space heating/cooling and
capacity shortage comfort problems is significant. In case of frequent domestic hot
water operation, frequent and long space heating/cooling interruptions will happen.
1.4 Contact/helpdesk number [6.3.2]
Setting Fill in…
Contact/helpdesk number