Thomas DryBox + AquaBox Parkett (786555) [41/48] Troubleshooting

Thomas DryBox + AquaBox Parkett (786555) [41/48] Troubleshooting
DryBOX
+
AquaBOX
Troubleshooting
GB
Problems / malfunctions Reason / remedy
General (all functions)
The appliance will not start Are the power cord, plug and socket intact?
Before checking, unplug the power cord; have all repairs carried
out by authorised specialists
Is the appliance switched on? Check
Dry vacuuming
Dust comes out of the appliance
during vacuuming
a) Using the DryBOX:
Are the lid of the DryBOX and the locking flaps at the front
correctly locked? Check
Is it possible that the DryBOX is too full? Empty/clean the
main cyclone if necessary
b) Using the AQUA box:
Is the aqua filter system fitted as described in the user manual?
Is there enough water in the waste water tank? Check
Suction power gradually decreases Is the special hygiene filter clogged? Clean the special
hygiene filter
Are the nozzles, suction pipe or hoses blocked by coarse dirt?
Stretch the hose during operation to loosen the blockage;
remove the blockage
Is the housing cover properly shut? Check
Insufficient suction power Is the ejector in the suction port clogged? Disassemble and
clean or rinse out with water
Is the special hygiene filter clogged? Clean the special
hygiene filter
Are the nozzles, suction pipe or hoses blocked by coarse dirt?
Disassemble and clean
Is the electronic suction power control set to MIN? Set the
suction power to MAX
Is the mechanical suction power control on the handle open?
Close the sliding button on the handle
Numerous water droplets on
the inside of the housing cover
There is probably too much dust in the aqua filter system
Clean the aqua filter system, change the water
Problems / malfunctions Cause / remedy
Wet vacuuming
The appliance switches off
during operation
Is the waste water tank full (float switch triggered)?
Empty it
Have you tilted or suddenly turned the appliance (float switch
triggered)? Make sure the appliance is level and switch it
on again.
Water comes out of the exhaust
openings
Is the float in the waste water tank dirty and stuck, which
means it can no longer respond when the tank is full?
Clean the float and the tank
An excessive pool of water collects
in the suction chamber (a few drops
are considered normal)
Are the gaskets and seal faces heavily soiled?
Clean them
Did you forget to put in the wet vacuuming insert? Check
41

Содержание

Похожие устройства

Скачать