Daikin FDBG60AVE [10/40] The auto swing function increases comfort level

Daikin FHC50KVE [10/40] The auto swing function increases comfort level
125FJ
44 39
71FJ
40 35
Switchable fan speed: High/Low
Programme "Dry"
Dehumidification is microprocessor con-
trolled to prevent abrupt and uncomforta-
ble changes in air temperature.
Indoor unit High Low
100FJ
43 38
Sliding shutter
Closes to moderate airflow (70%)
Heat exchanger
Ultra-thin, quiet design made possible by new Flat Turbo Fan.
The auto-swing function increases comfort level
Auto-swing between 0° and
60°
Auto-swing
Settable to 5 different levels
between 0° and 60°
5-levels air direction setting
The air direction is set automatically to
the memorised position of the previous
air direction. (Initial setting is 60° for
heating and 30° for cooling.)
Auto-air direction control
18
2-way
flow
3-way
flow
4-way
flow
Note: When 2- or 3-way flow configurations are selected, the unused flow outlets must be blocked off with the optional sealing
material. Sound during operation will rise by about 2 dB.
Two selectable temperature-sensors
Both indoor unit and wired remote con-
troller (option) contain temperature-
sensors. Temperature sensing can be
set at the unit or, to further improve
comfort level, closer to the target area
at the wired remote control.
Ultra-thin with quiet operation
Thinner usually means noisier, but
Daikin's exclusive technology has
solved this.
Through use of a high-static-pressure
vane and a thorough reduction in flow
loss in the path between internal fan
suction and air output, we have ach-
ieved a thinner fan unit and quiet opera-
tion while maintaining airflow.
CEILING SUSPENDED CASSETTE TYPE
Standard (100%)
Moderate (approx. 70%)
3-Way Air Flow 4-Way Air Flow
3.0 m
3.3 m
3.5 m
2.7 m
3.0 m
3.5 m
40
/
35
dB(A)
FUY71FJ
High Low
Sound level
17
At heating startup and thermo OFF*, air direction is automatically set to
horizontal
Draft prevention (in heating)
Easier to maintain
Suitable for high ceilings
Criteria for ceiling height and number of
air discharge outlets
Number of air discharge outlets used
2-way flow 3-way flow 4-way flow
Standard
High ceiling 1
High ceiling 2
3.5 m
3.8 m
Ceiling
height
Quick and easy to install
Drain pump is equipped as
standard accessory with
500
mm
lift.
Air direction can be selected according to installation
Accessible from below for easy
maintenance
Long-life filter lasts about 1 year *
Maintenance not required
* For dust concentration of 0.15 mg/m
3
Simply lock the body
in place with suspen-
sion bolts to install.
Adjustment is
smooth and simple,
too.
Simple installation procedure
Note: The panel cannot be
turned when the wireless
remote controller is in
use.
Suspension bolt
T-type hexagon wrench
Hook
500
mm
Low gas pressure detection
Flexibility in installation location.
Installation is also simple.
Selection patterns for air direction and fan speed ratio
Note: Applicable only to the flow configurations shown below.
*Requires s ealing member for air disc harge
outlet (optional ac ces s ory) for oppos ing 2-
Piping
position
*When the thermostat turns off.
*
Temperature-sens or on indoor unit mus t be used
when the air conditioner is controlled from another
room.
**Wireless remote controller does not have a
Wired LCD remote controller Wireless LCD remote controller
A signal rec eiver must be
added to the indoor unit.
Wireles s remote
controller and
signal rec eiver unit
are sold as a set.
Note: R emote controller cable not
included. C ables must be
procured locally.
Accessory required for indoor unit (option)
BRC1C61
CEILING
SUSPENDED CASSETTE
TYPE
FUY
FUY71FJV1–125FJV1Cooling only
FUY71FJV1–125FJV1Heat pump
Feature
Features (Features are explained on P. 37–38.)
Model
Heat pump
*1
*
1
Applic able when wired remote c ontroller is used
*
2
Applic able to R 71LU– 125LU outdoor units (for temp. down to 15°C )
(An option is required.)
Cooling only
*1
*3
*2
*4
*4
*4
*4
Mould
prevention
Comfort Work & Servicing Control features
Others
S wing pattern s elec tion
Draft prevention function
S witc hable fan s peed
Auto-swing
Programme "Dry"
High c eiling applic ation
Hot start
Year-round c ooling
applicable
Timer s elec tor
Drain pump mec hanism
Pre c harged for
up to 30 m
Long-life filter
Mould res istant treatment
for filter
Filter sign
Low gas pres s ure
detec tion
E mergency operation
S elf-diagnosis func tion
C ontrol by 2 remote
controllers
Auto-c ooling/heating
change-over
Auto-res tart
C ontrol by 1 remote
controller
E xternal c ommand
control
C entral remote
control
Interloc k c ontrol
PE fin
Mould-proofing
drain pan
Two s elec table
temperature-sens ors
Guide Line up
P. 3–4, 7–8
Outdoor units
P. 33–34
Options
P. 57
Outer dimension drawings
P. 61
Remote controllers
P. 35–36
Standard specifications
P. 40 and 50
*
3
Applic able to R Y71L U– 125LU outdoor units (for temp. down to 5°C )
*
4
Applic able to R (Y)71L U– 125LU outdoor units
BRC7C528W
Cooling only
BRC7C529W
Heat pump
Note: Initial s ettings are for s tandard ceiling
height and 4-way flow. High c eiling s ettings
1 and 2 are set from the remote
Signal receiver unit
(Installed type)
Note : Anec hoic chamber c onvers ion value,
meas ured ac c ording to JIS parameters and
dB(A)
Installable in any direction
Since the orientation of the intake grill can
be adjusted after installing, the direction of
the intake grill lines
can be unified when
multiple units are in-
stalled.