Candy PMI 640 N [19/86] Changing the jets

Содержание

KST Changing the gas type The calorific power output and gas pressure will vary according to the gas supply Burner setting must be carried out once the gas and electrical installation is complete When changing gas type you must follow the procedure below fit the correct jets adjust the minimum flame on the taps see page 23 G20 GAZ GAS 5 0 Z LU G25 G30 G31 20 mbar 25 mbar 29 mbar 37 mbar CAT II2E 3 FR BE CAT II2H3 ES GB GR IT PT CAT II2H3B P HR RO CAT II2L3B P NL CAT I2E PL a a a X X X X X a X a n Factory setting Natural gas G20 20 mbar G25 25 mbar X Gas setting possible according to installation Butane gas G30 29 mbar or Propane gas G31 37 mbar Changing the jets The gain access to the jets remove the pan supports and remove the burner cap and body Take a spanner and unscrew the jet According to the table below fit the correct jet for the type of gas to be used Secure the jet tightly Place the burner body cap and pan support Each jet is designated by size HOB BURNERS front left rapid front right auxiliary rear semi rapid Jet 0 83 0 83 0 90 0 50 0 50 kW 1 00 1 00 1 00 1 00 1 00 Jet 1 00 1 00 1 10 0 65 0 65 kW 1 70 1 70 1 70 1 70 1 70 Jet 1 20 1 20 1 35 0 85 0 85 kW 2 70 2 70 2 70 2 70 2 70 0 45 1 00 0 60 1 70 0 70 2 70 0 50 1 00 0 65 1 75 0 85 2 95 1 10 1 00 1 00 1 00 1 00 1 35 1 00 1 10 kW power Factory setting G 20 20 mbar G 25 25 mbar 1 85 1 70 1 70 1 70 1 20 1 20 1 70 1 35 2 95 2 65 2 70 2 70 mbar Gas 20 G 20 25 G 25 G 25 20 G 30 29 37 G 31 G 30 50 G 31 G 30 37 G 31 G 20 25 G 25 1 25 G 2 350 13 G 27 20 0 83 0 83 1 10 0 90 19