GAS and MIXED LU For the 1 5mm2 2G 2E hobs the rated These hobs are delivered with cable Connection is exclusively envisaged under tensions of 220 240V Between phases or between phases and neutral Connect 10 16 amperes to an outlet The eventual replacement of the supplying cord must be carried on by the After Sales Service or by an agreed engineer with a cord whose characteristics must be similar to the original one For the 4G hobs supplying cord type H05VV F section 3G 0 75mm2 For the 3G E hobs the rated current is 8 6A Supplying cord type H05W F section 3G1 mm2 current is 13 6A Supplying cord type H05W F section 3G Regulating the flame Setting idle flame If you have changed the type of gas it is important to verify the flame stability at the minimum regulation Gaing Access to the by pass screw To gain access to hob burner by pass screws remove the knobs from the control panel Never loosen the others screws REGULATING THE MINIMUM FLAME ON THE HOB BURNER a Natural gas simply loosen the screw switch on the burner and turn the knob to minimum Turn the by pass screw until a low flame is visible Turn the control knob from minimum to maximum position to check that it is satisfactory b Butane propane gas The by pass screw should locked be screwed 23 fully home without being