1 ■English
Safety Precautions
• The precautions described herein are classified as WARNING and CAUTION. They both contain important informa-
tion regarding safety. Be sure to observe all precautions without fail.
• Meaning of WARNING and CAUTION notices
WARNING .... Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION .....Failure to observe these instructions properly may result in property damage or personal injury, which
may be serious depending on the circumstances.
• The safety marks shown in this manual have the following meanings:
• After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate
the air conditioner and take care of it with the aid of the operation manual.
Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt.
WARNING
• Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
• Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
• Electrical work must be performed in accordance with relevant local and national regulations and with instructions
in this installation manual. Be sure to use a dedicated power supply circuit only.
Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.
• Use a cable of suitable length.
Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.
• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal con-
nections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.
• If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
• After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks
into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker.
• When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air,
and use only the specified refrigerant (R410A).
The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and
even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pressure in
the refrigeration cycle, which may result in equipment damage and even injury.
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.
• Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead.
Imperfect earthing may result in electric shocks.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks or fire.
CAUTION
• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
• While following the instructions in this installation manual, install drain piping to ensure proper drainage and insu-
late piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
01_EN_3P207052-2A.fm Page 1 Monday, December 1, 2008 11:40 AM
Содержание
- Installation manual 1
- Models atxs20g2v1b atxs25g2v1b atxs35g2v1b atxs42g2v1b atxs50g2v1b 1
- R410a split series 1
- Umeda center bldg 2 4 12 nakazaki nishi kita ku osaka 530 8323 japan 2
- Caution 3
- English 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Choosing an installation site 4
- English 2 4
- Indoor unit 4
- Wireless remote controller 4
- Caution 5
- Installation tips 5
- Removing and installing front grille 5
- Removing and installing front panel 5
- When there is no work space because the unit is close to ceiling 5
- English 4 6
- How to set the different addresses 6
- Removal methods of metal plate electrical wiring covers 6
- When connecting to an ha system wired remote controller central remote controller etc 6
- Attachment methods of metal plate electrical wiring covers 7
- Caution 7
- English 7
- Installation tips 7
- Caution 8
- English 6 8
- Indoor unit installation drawings 8
- Intelligent eye sensor 8
- English 9
- Indoor unit installation 9
- Installing the mounting plate 9
- Boring a wall hole and installing wall embedded pipe 10
- English 8 10
- Installing indoor unit 10
- Right side right back or right bottom piping 10
- 2 left side left back or left bottom piping 11
- 3 wall embedded piping 11
- Attachment on the left side 11
- Attachment on the right side factory default 11
- Do not apply lubricating oil refrigeration oil when inserting application of causes deterioration and drain leakage of the plug 11
- English 11
- How to set drain plug 11
- How to set the drain hose 11
- Indoor unit installation 11
- Insert drain hose and tighten fixing screw forgetting to attach this may cause water leakages 11
- Left bottom piping 11
- Left side piping left back piping 11
- Mounting plate 11
- No gap 11
- Remove pipe port cover here for left side piping 11
- Drain piping 12
- English 10 12
- Warning 12
- Wiring 12
- Caution 13
- Flaring the pipe end 13
- Refrigerant piping 13
- Refrigerant piping work 13
- Warning 13
- Caution 14
- English 12 14
- How to force cooling operation mode 14
- Pump down operation 14
- Test items 15
- Trial operation and testing 15
- Trial operation from remote controller 15
- P207052 2a m07b017a 16
Похожие устройства
- Daikin ATXS35G2V1B Инструкция по эксплуатации
- Daikin ATXS35G2V1B Сервис мануал
- Daikin ATXS42G2V1B Инструкция по монтажу
- Daikin ATXS42G2V1B Инструкция по эксплуатации
- Daikin ATXS42G2V1B Сервис мануал
- Daikin ATXS50G2V1B Инструкция по монтажу
- Daikin ATXS50G2V1B Инструкция по эксплуатации
- Daikin ATXS50G2V1B Сервис мануал
- Daikin ATX20JV1B Инструкция по эксплуатации
- Daikin ATX20JV1B Технические данные
- Daikin ATX20JV1B Сервис мануал
- Daikin ATX25JV1B Инструкция по эксплуатации
- Daikin ATX25JV1B Технические данные
- Daikin ATX25JV1B Сервис мануал
- Daikin ATX35JV1B Инструкция по эксплуатации
- Daikin ATX35JV1B Технические данные
- Daikin ATX35JV1B Сервис мануал
- АМАТЕК AC-HDV503SS Инструкция по эксплуатации
- АМАТЕК AC-HD502 Инструкция на OSD меню HD видеокамер Amatek
- АМАТЕК AC-HD502 Инструкция по эксплуатации