Daikin RKS60F2V1B [2/31] Specifications

Daikin RKS60F2V1B [2/31] Specifications
3
1
2
Split Sky Air • Outdoor Units
2
Outdoor Units • R-410A • RKS-F2V1B
2 Specifications
2-1 NOMINAL CAPACITY AND
NOMINAL INPUT
RKS25F2V1B RKS35F2V1B RKS50F2V1B RKS60F2V1B RKS71FV1B
For
combination
indoor units +
outdoor units
Indoor Units FVXS25FV1B FVXS35FV1B FTKS50FV1B FTKS60FV1B FTKS71FV1B
Cooling
capacity
Minimum kW 1.3 1.4 1.7 1.7 2.3
Standard kW 2.5 3.5 5.0 6.0 7.1
Maximum kW 3.0 3.8 6.0 6.7 8.5
Nominal input Cooling Minimum kW 0.30 0.30 0.44 0.44 0.57
Standard kW 0.57 1.02 1.55 1.99 2.35
Maximum kW 0.92 1.25 2.08 2.40 3.20
For
combination
indoor units +
outdoor units
EER Nominal 4.39 3.43 3.23 3.02 3.02
Energy
Labeling
Directive
Cooling A A A B B
Annual energy consumption kWh 285 510 775 995 1175
Indoor Units FCQ35C7VEB FVXS50FV1B FDKS60CVMB
Cooling
capacity
Minimum kW 1.4 1.4 1.7
Standard kW 3.4 5.0 6.0
Maximum kW 3.7 5.6 6.5
Nominal input Cooling Minimum kW 0.50 0.44
Standard kW 0.95 1.55 2.13
Maximum kW 2.00 2.49
For
combination
indoor units +
outdoor units
EER Nominal 3.58 3.23 2.82
Energy
Labeling
Directive
Cooling A A C
Annual energy consumption kWh 475 775 1065
Indoor Units FDKS50CVMB FCQ60C7VEB
Cooling
capacity
Minimum kW 1.7 0.9
Standard kW 5.0 5.7
Maximum kW 5.3 6.0
Nominal input Cooling Minimum kW 0.44
Standard kW 1.65 1.64
Maximum kW 1.93
For
combination
indoor units +
outdoor units
EER Nominal 3.03 3.48
Energy
Labeling
Directive
Cooling B A
Annual energy consumption kWh 825 820
Indoor Units FLKS50BAVMB FFQ60B8V1B
Cooling
capacity
Minimum kW 1.7
Standard kW 4.9 5.8
Maximum kW 5.3
Nominal input Cooling Minimum kW 0.44
Standard kW 1.72 2.07
Maximum kW 1.95
For
combination
indoor units +
outdoor units
EER Nominal 2.85 2.80
Energy
Labeling
Directive
Cooling C D
Annual energy consumption kWh 860 1035
Indoor Units FTKS50D2V1W FBQ60B8V1
Cooling
capacity
Minimum kW 1.7
Standard kW 5.0 5.7
Maximum kW 5.2
Nominal input Cooling Minimum kW 0.44
Standard kW 1.65 2.19
Maximum kW 1.82