Daikin RKS60E2V1B [21/38] 3 electrical specifications

Daikin RKS60E2V1B [21/38] 3 electrical specifications
3
1
1
Split Sky Air Outdoor Units 4
Outdoor Units R-410A RXS-E2V1B
1 Specifications
Piping
connections
Liquid (OD) Diameter
(OD)
mm 6.35 6.35 6.35
Gas Diameter
(OD)
mm 12.7 12.7 15.9
Drain Diameter
(OD)
mm 18 18 18
Piping Length Maximum m 30 30 30
Additional Refrigerant
Charge
kg/m 0.02/>10m
Max. internunit level
difference
m 20.0 20.0 20.0
Heat Insulation Both liquid and gas pipes
Standard
Accessories
Item Installation manual
Quantity 1 1 1
Notes Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35° CDB,
equivalent refrigerant piping : 7.5m, level difference : 0m.
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB,
equivalent refrigerant piping : 5m, level difference : 0m
Sound levels are measured in an anechoic room
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details,
please refer to sound level drawings of this chapter.
The sound power level is an absolute value indicating the power which a sound source generates.
1-3 ELECTRICAL SPECIFICATIONS
RXS5 0E2V1B RXS6 0E2V1B R XS71 E2 V1 B
Power Supply Name V1
Phase 1 1 1
Frequency Hz 50 50 50
Voltage V 220-240
Voltage range Minimum V -10%
Maximum V +10%
Current Nominal
running current
(RLA)
Cooling
(A)
A 6.75 8.62 10.70
Heating
(A)
A 6.94 8.80 10.78
Starting current (cooling/
heating)
A 7.1 9.0 11
Z-max List No requirements
Wiring
connections
For Power
Supply
Quantity 3 3 3
For connection
with indoor
Quantity 4 4 4
Remark included earth wiring
Power Supply Intake Outdoor unit only Indoor unit only Outdoor unit only
1-2 TECHNICAL SPECIFICATIONS