Daikin FTKS60EV1B [203/258] Removal of the electrical box pcb swing motor

Daikin RN60E2V1B [203/258] Removal of the electrical box pcb swing motor
Indoor Unit SiBE04-609
194 Removal Procedure
1.2.4 Removal of the Electrical Box / PCB / Swing Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the front grille.
Parts layout
2. Remove the drip proof
plate.
1
Loosen the screw.
3. Disconnect the indoor
heat exchanger thermistor
and the earth.
Mind that not to lose the clip
for the thermistor.