Daikin RKS71FVM [13/125] Room air conditioners f series

Daikin RKS50FVM [13/125] Room air conditioners f series
Specifications ED04-702
12 Room Air Conditioners F-Series
50Hz 220-230-240V / 60Hz 220-230V
Note:
The data are based on the conditions shown in the table below.
Model
Indoor Units FTXS71FVMA
Outdoor Units
RXS71FVMA
Cooling Heating
Capacity
Rated (Min.~Max.)
kW 7.1 (2.3~8.5) 8.2 (2.3~10.0)
Btu/h 24,200 (7,800~29,000) 28,000 (7,900~34,100)
kcal/h 6,110 (1,980~7,310) 7,050 (1,980~8,600)
Running Current Rated A 10.8-10.4-9.9/10.8-10.4 11.6-11.1-10.6/11.6-11.1
Power Consumption
Rated (Min.~Max.)
W 2,360 (570~3,200) 2,520 (520~3,730)
Power Factor (Rated) % 99.3-98.7-99.3/99.3-98.7 98.7-98.7-99.1/98.7-98.7
COP
Rated (Min.~Max.)
W/W 3.01 (4.04~2.66) 3.25 (4.42~2.68)
Piping
Connections
Liquid mm
φ
6.4
Gas mm
φ
15.9
Drain mm
φ
18.0
Heat Insulation Both Liquid and Gas Pipes
Max. Interunit Piping Length m 30
Max. Interunit Height Difference m 20
Chargeless m 10
Amount of Additional Charge of
Refrigerant
g/m 20
Indoor Unit FTXS71FVMA
Front Panel Color White
Air Flow Rate
m³/min
(cfm)
H 17.4 (614) 21.5 (759)
M 14.6 (516) 18.0 (636)
L 11.9 (420) 14.4 (508)
SL 11.2 (395) 13.3 (470)
Fan
Type Cross Flow Fan
Motor Output W 43
Speed Steps 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof
Running Current (Rated) A 0.21-0.20-0.19/0.21-0.20 0.28-0.27-0.26/0.28-0.27
Power Consumption (Rated) W 45 60
Power Factor % 97.4-97.8-98.7/97.4-97.8 97.4-96.6-96.2/97.4-96.6
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 290×1,050×238
Packaged Dimensions (H×W×D) mm 337×1,147×366
Weight kg 12
Gross Weight kg 17
Operation
Sound
H/M/L/SL dBA 46/42/37/34 46/42/37/34
Outdoor Unit RXS71FVMA
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 2YC63BXD
Motor Output W 1,920
Refrigerant
Oil
Model FVC50K
Charge L 0.75
Refrigerant
Model R-410A
Charge kg 2.3
Air Flow Rate m³/min (cfm)
HH 57.1 (2,016)
H 54.5 (1,924) 52.5 (1,854)
L 46.0 (1,624) 52.5 (1,854)
Fan
Type Propeller
Motor Output W 66
Running Current (Rated) A 10.59-10.20-9.71/10.59-10.20 11.32-10.83-10.34/11.32-10.83
Power Consumption (Rated) W 2,315 2,460
Power Factor % 99.4-98.7-99.3/99.4-98.7 98.8-98.8-99.1/98.8-98.8
Starting Current A 11.6
Dimensions (H×W×D) mm 770×900×320
Packaged Dimensions (H×W×D) mm 900×925×390
Weight kg 71
Gross Weight kg 78
Operation Sound dBA H:52 SL:49 L:52 SL:49
Drawing No. 3D054881A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling Heating Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m

Содержание

Скачать