Daikin RKS71FVM [24/125] Ed04 702 capacity tables

Daikin RKS50FVM [24/125] Ed04 702 capacity tables
ED04-702 Capacity Tables
Room Air Conditioners F-Series 23
8. Capacity Tables
8.1 Cooling Only
FTKS50FVM + RKS50FVM (50Hz 220-240V / 60Hz 220-230V)
3D056391
FTKS60FVM + RKS60FVM (50Hz 220-240V / 60Hz 220-230V)
3D056392
AFR 14.7
BF 0.28
INDOOR OUTDOOR TEMPERATURE(°CDB)
EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 5.123.611.194.893.491.304.663.371.424.563.321.464.423.251.534.193.131.65
16.0 22 5.353.551.205.123.431.314.893.321.434.793.271.474.653.211.544.423.101.65
18.0 25 5.583.691.205.353.581.325.123.471.435.023.431.484.883.371.554.653.261.66
19.0 27 5.70 3.86 1.21 5.47 3.75 1.32 5.23 3.65 1.44 5.14 3.61 1.48
5.00 3.55 1.55 4.77 3.45 1.66
22.0 30 6.043.711.225.813.621.335.583.521.455.493.491.495.353.431.565.113.351.67
24.0 32 6.273.601.226.043.521.345.813.431.455.723.401.505.583.351.575.343.271.68
Symbols NOTE:
AFR : Air flow rate (m³/min.) 1. Capacities are based on the following conditions.
(1) Corresponding refrigerant piping length : 7.5m
(2) Level difference : 0m
2. shows nominal (rated) capacities and power input.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C)
EDB : Entering dry bulb temp. (°C)
TC : Total capacity (kW)
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
AFR 16.2
BF 0.29
INDOOR OUTDOOR TEMPERATURE(°CDB)
EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 5.603.941.495.603.941.665.593.941.825.483.881.885.313.791.975.033.642.12
16.0 22 6.424.171.546.144.021.685.863.881.835.753.821.895.593.741.985.313.602.12
18.0 25 6.704.311.546.424.171.696.144.041.846.033.991.905.863.911.995.583.782.13
19.0 27 6.84 4.49 1.55 6.56 4.36 1.70 6.28 4.23 1.84 6.17 4.18 1.90
6.00 4.10 1.99 5.72 3.98 2.14
22.0 30 7.254.311.566.974.191.716.694.081.866.584.041.916.413.972.006.143.862.15
24.0 32 7.534.181.577.254.071.726.973.971.866.863.931.926.693.872.016.413.772.16
Symbols NOTE:
AFR : Air flow rate (m³/min.) 1. Capacities are based on the following conditions.
(1) Corresponding refrigerant piping length : 7.5m
(2) Level difference : 0m
2. shows nominal (rated) capacities and power input.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C)
EDB : Entering dry bulb temp. (°C)
TC : Total capacity (kW)
SHC : Sensible heat capacity (kW)
PI : Power input (kW)