Flex H 1127 VE [13/190] Safety instructions

Flex H 1127 VE [13/190] Safety instructions
H 1105 VE/H 1127 VE
13
Safety instructions
t^okfkd>
oÉ~Ç=~ää=ë~ÑÉíó=áåëíêìÅíáçåë=~åÇ=çíÜÉê=
áåëíêìÅíáçåë K=
c~áäìêÉ=íç=çÄëÉêîÉ=íÜÉ=ë~ÑÉ íó=
áåëíêìÅíáçåë=~åÇ=çíÜÉê=áåëíêìÅíáçåë=ã~ ó=êÉëìäí=
áå ~å=ÉäÉÅíêáÅ=ëÜçÅâI=ÑáêÉ=~åÇLçê=ëÉêáçìë=áåàìêáÉë
K=
hÉÉé=~ää=ë~ÑÉíó=áåëíêìÅíáçåë=~åÇ=çíÜÉê=
áåëíêìÅíáçåë=áå=~=ë~ÑÉ=éä~ÅÉ=Ñçê=íÜÉ=ÑìíìêÉK
This electric power tool must be used as
a sander. Observe all safety information,
instructions, diagrams and data which
you receive with the power tool.
If you do not observe the following
instructions, an electric shock, fire and/or
serious injuries may occur.
This electric power tool is not suitable for
use with sandpaper, wire brushes, or for
polishing and cut-off grinding.
Applications for which the power tool is not
designed can cause hazards and injuries.
Never use accessories which the
manufacturer did not intend or
recommend especially for this electric
power tool.
Just because you can attach the accessory to
your electric power tool does not guarantee
safe use.
The permitted speed of the insertion tool
must be at least as high as the maximum
speed indicated on the electric power
tool.
An accessory which rotates faster than
permitted may shatter and fly off.
Outer diameter and thickness of the
insertion tool must correspond to the
dimensions of the electric power tool.
Incorrectly measured insertion tools cannot
be adequately shielded or controlled.
Sanding discs, sanding wheels or other
accessories must fit precisely on the
grinding spindle of your power tool.
Insertion tools, which do not fit exactly on the
grinding spindle of the electric power tool,
rotate unevenly, vibrate violently and may
result in loss of control.
"Arbor-mounted discs, sanding
cylinders, cutting tools or other
accessories must be fully inserted in the
drill collet or chuck. The "protrusion" or
exposed section of the arbor between the
sanding medium and collet or chuck
must be minimal.
If the arbour is not clamped sufficiently or the
sanding medium extends too far, the insert
can work loose and be ejected under high
speed.
Do not use a damaged accessory. Before
each use, check the inserts for chips and
cracks, wear and tear. If the electric
power tool or the insertion tool is
dropped, check for damage or use an
undamaged insertion tool. When you
have checked and inserted the tool,
ensure that you and anybody in the
vicinity remain outside the plane of the
rotating insertion tool and leave the
power tool running for one minute at
maximum speed.
Damaged insertion tools usually break during
this test time.
Wear personal protective equipment.
Depending on the application, wear
full face protection, eye protection or
goggles. If appropriate, wear a dust
mask, hearing protection, protective
gloves and/or a special apron which
protect you from small sanding and
material particles.
You should protect your eyes from foreign
objects which are ejected for different
applications. Dust and respirator masks must
filter the dust which is generated by the power
tool for the particular application. If you are
exposed to loud noise for a prolonged period,
you may suffer hearing loss.
Ensure that other persons are situated
at a safe distance from the work area.
Anyone who enters the work area must
wear personal protective equipment.
Fragments of the workpiece or broken
insertion tools may fly off and cause injuries
even outside the direct working area.
If the insertion tool is at risk of coming
into contact with concealed power cables
or the power cord itself, hold the power
tool by the insulated grip surfaces only.
Contact with a live cable may also cause
metal parts of the appliance to become live
and result in an electric shock.

Содержание

H 1105 VE H 1127 VE Safety instructions A WARNING Read all safety instructions and other instructions Failure to observe the safety instructions and other instructions may result in an electric shock fire and or serio us injuries Keep all safety instructions and other instructions in a safe place for the future This electric power tool must be used as a sander Observe all safety information instructions diagrams and data which you receive with the power tool If you do not observe the following instructions an electric shock fire and or serious injuries may occur This electric power tool is not suitable for use with sandpaper wire brushes or for polishing and cut off grinding Applications for which the power tool is not designed can cause hazards and injuries Never use accessories which the manufacturer did not intend or recommend especially for this electric power tool Just because you can attach the accessory to your electric power tool does not guarantee safe use The permitted speed of the insertion tool must be at least as high as the maximum speed indicated on the electric power tool An accessory which rotates faster than permitted may shatter and fly off Outer diameter and thickness of the insertion tool must correspond to the dimensions of the electric power tool Incorrectly measured insertion tools cannot be adequately shielded or controlled Sanding discs sanding wheels or other accessories must fit precisely on the grinding spindle of your power tool Insertion tools which do not fit exactly on the grinding spindle of the electric power tool rotate unevenly vibrate violently and may result in loss of control Arbor mounted discs sanding cylinders cutting tools or other accessories must be fully inserted in the drill collet or chuck The protrusion or exposed section of the arbor between the en sanding medium and collet or chuck must be minimal If the arbour is not clamped sufficiently or the sanding medium extends too far the insert can work loose and be ejected under high speed Do not use a damaged accessory Before each use check the inserts for chips and cracks wear and tear If the electric power tool or the insertion tool is dropped check for damage or use an undamaged insertion tool When you have checked and inserted the tool ensure that you and anybody in the vicinity remain outside the plane of the rotating insertion tool and leave the power tool running for one minute at maximum speed Damaged insertion tools usually break during this test time Wear personal protective equipment Depending on the application wear full face protection eye protection or goggles If appropriate wear a dust mask hearing protection protective gloves and or a special apron which protect you from small sanding and material particles You should protect your eyes from foreign objects which are ejected for different applications Dust and respirator masks must filter the dust which is generated by the power tool for the particular application If you are exposed to loud noise for a prolonged period you may suffer hearing loss Ensure that other persons are situated at a safe distance from the work area Anyone who enters the work area must wear personal protective equipment Fragments of the workpiece or broken insertion tools may fly off and cause injuries even outside the direct working area If the insertion tool is at risk of coming into contact with concealed power cables or the power cord itself hold the power tool by the insulated grip surfaces only Contact with a live cable may also cause metal parts of the appliance to become live and result in an electric shock 13