Daikin ATXS35BVMB [11/14] Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand then tighten them fully with the torque wrenches use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and escaping gas
![Daikin FTX25BVMB [11/14] Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand then tighten them fully with the torque wrenches use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and escaping gas](/views2/1778712/page11/bgb.png)
■English 10
Refrigerant piping work
,
install as described in the installation manual supplied with the Multi outdoor unit.
1.
Flaring the pipe end.
1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing downward so that the chips do not enter the
pipe.
3) Put the flare nut on the pipe.
4) Flare the pipe.
5) Check that the flaring is properly made.
■
■■
■
Warning
1) Do not use mineral oil on flared part.
2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
3) Never use piping which has been used for previous installations. Only use parts which are delivered with the unit.
4) Do never install a drier to this R-410A unit in order to guarantee its lifetime.
5) The drying material may dissolve and damage the system.
6) Incomplete flaring may cause refrigerant gas leakage.
2.
Refrigerant piping.
1) Align the centres of both flares and tighten the flare nuts 3 or 4 turns by
hand. Then tighten them fully with the torque wrenches.
• Use torque wrenches when tightening the flare nuts to prevent damage
to the flare nuts and escaping gas.
2) To prevent gas leakage, apply refrigeration machine oil on both inner and outer surfaces of the flare. (Use refrigeration oil
for R-410A)
2-1.
Caution on Piping Handling
1) Protect the open end of the pipe against dust and moisture.
2) All pipe bends should be as gentle as possible. Use a pipe bender
for bending.
(Bending radius should be 30 to 40 mm or larger.)
With a Multi indoor unit
(Cut exactly at
right angles.) Remove burrs
Set exactly at the position shown below.
A
IMPERIAL
RIGID
1.0 mm
0.5 mm
Flaring
A
Die
Check
Flare’s inner
surface must
be flaw-free.
The pipe end must
be evenly flared in
a perfect circle.
Make sure that the
flare nut is fitted.
Flare nut tightening torque
Gas side Liquid side
3/8 inch 1/4 inch
32.7-39.9N
l
m 14.2-17.2N
l
m
(333-407kgf
l
cm) (144-175kgf
l
cm)
Valve cap tightening torque
Gas side Liquid side
3/8 inch 1/4 inch
21.6-27.4N
l
m 21.6-27.4N
l
m
(220-280kgf
l
cm) (220-280kgf
l
cm)
Coat here with refrigeration machine oil
Torque wrench
Piping union
Flare nut
Spanner
Wall
If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.
Be sure to
place a cap.
Rain
01_EN_2P098777-1.fm Page 10 Friday, October 18, 2002 1:26 PM
Содержание
- Ftxs25bvmb ftks25bvmb ftxs35bvmb ftks35bvmb ftx25bvmb ftk25bvmb ftx35bvmb ftk35bvmb atxs25bvmb atks25bvmb atxs35bvmb atks35bvmb atx25bvmb atk25bvmb atx35bvmb atk35bvmb 1
- Installation manual 1
- Models 1
- R 410a split series 1
- Cautions 2
- I english 2
- Safety precautions 2
- Warnings 2
- Accessories 3
- Choosing a site 3
- How to remove the front grille 3
- I english 2 3
- Indoor unit 3
- Installation tips 3
- Wireless remote controller 3
- How to attach the front grille 4
- How to attach the front panel 4
- How to remove the front panel 4
- How to set te different addresses 4
- I english 4
- Installation tips 4
- Pcb in the indoor unit 4
- Wireless remote controller 4
- Ftx25 35 ftk25 35 atx25 35 atk25 35 5
- Ftxs25 35 ftks25 35 atxs25 35 atks25 35 5
- I english 4 5
- Indoor unit installation drawings 5
- Install air puriying filter on air filter 5
- Adjusting the angle 6
- Iiii caution 6
- Intelligent eye sensor 6
- Boring a wall hole and installing wall embedded pipe 7
- I english 6 7
- Indoor unit installation 7
- Installing the mounting plate 7
- 2 left side left back or left bottom piping 8
- Caulk this hole with putty or caulking material bind with plastic tape 8
- Do not apply lubricating oil refrigerant machine oil when inserting application of causes deterioration and drain leakage of the plug 8
- Drain hose 8
- I english 8
- Indoor unit installation 8
- Insert a hexagon wrench 4 mm 8
- Installing indoor unit 8
- No gap 8
- Wrap insulating tape around the bent portion of refrigerant pipe overlap at least half the width of the tape with each turn interconnecting wires 8
- _en_2p098777 1 fm page 7 friday october 18 2002 1 26 pm 8
- 3 wall embedded piping 9
- I english 8 9
- Iiii warning 9
- Wiring 9
- _en_2p098777 1 fm page 8 friday october 18 2002 1 26 pm 9
- Drain piping 10
- I english 10
- Indoor unit installation 10
- When connecting to an ha system 10
- Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand then tighten them fully with the torque wrenches use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and escaping gas 11
- Cut the pipe end with a pipe cutter 2 remove burrs with the cut surface facing downward so that the chips do not enter the pipe 3 put the flare nut on the pipe 4 flare the pipe 5 check that the flaring is properly made 11
- Do not use mineral oil on flared part 2 prevent mineral oil from getting into the system as this would reduce the lifetime of the units 3 never use piping which has been used for previous installations only use parts which are delivered with the unit 4 do never install a drier to this r 410a unit in order to guarantee its lifetime 5 the drying material may dissolve and damage the system 6 incomplete flaring may cause refrigerant gas leakage 11
- Flaring the pipe end 11
- Iiii warning 11
- Protect the open end of the pipe against dust and moisture 2 all pipe bends should be as gentle as possible use a pipe bender for bending bending radius should be 30 to 40 mm or larger 11
- Refrigerant piping 11
- Refrigerant piping work 11
- To prevent gas leakage apply refrigeration machine oil on both inner and outer surfaces of the flare use refrigeration oil for r 410a 11
- 2 selection of copper and heat insulation materials 12
- I english 12
- Refrigerant piping work 12
- I english 12 13
- Test items 13
- Trial operation and testing 13
- Trial operation from remote controller 13
- P098777 1 m02b078 14
Похожие устройства
- Daikin ATXS35BVMB Сервис мануал
- Daikin ATKS25BVMB Инструкция по монтажу
- Daikin ATKS25BVMB Сервис мануал
- Daikin ATKS35BVMB Инструкция по монтажу
- Daikin ATKS35BVMB Сервис мануал
- Daikin ATX25BVMB Инструкция по монтажу
- Daikin ATX25BVMB Сервис мануал
- Daikin ATX35BVMB Инструкция по монтажу
- Daikin ATX35BVMB Сервис мануал
- Daikin ATK25BVMB Инструкция по монтажу
- Daikin ATK25BVMB Сервис мануал
- Daikin ATK35BVMB Инструкция по монтажу
- Daikin ATK35BVMB Сервис мануал
- Daikin FTS20BVMB Технические данные
- Daikin FTS20BVMB Инструкция по эксплуатации
- Daikin FTS20BVMB Сервис мануал
- Daikin FTS25BVMB Инструкция по эксплуатации
- Daikin FTS25BVMB Технические данные
- Daikin FTS25BVMB Сервис мануал
- Daikin FTS35BVMB Инструкция по эксплуатации