Daikin FHC40JEV1K [4/24] Outline and dimensions
![Daikin RD50JEY1K [4/24] Outline and dimensions](/views2/1784692/page4/bg4.png)
OUTLINE AND DIMENSIONS
Outdoor Unit
N
L
K L
TN
M
A
D
O
PBQ
R
S
C
H
G
F
E
I J
All dimensions are in mm
Dimension
Model
A B C D E F G H I J K L M N O P Q R S T
RD20JEV1K 855 628 328 520 181 44 93 149 101 113 603 126 164 17 34 3 23 73 75 362
RD25/30JEV1K 855 730 328 520 182 44 93 149 101 113 603 126 164 17 34 3 23 73 75 362
Indoor Unit
All dimensions are in mm
Dimension
Model
A B C D E F G H I J K L M N
FDM50JEV1K 359 1369 1326 1287 594 384 541 256 173 306 256 161 248 220
FDM60JEV1K 359 1569 1526 1487 694 378 541 256 173 306 356 161 248 220
E E
A AK
B
C
K
D
M N
L
F
I
G
H
J
Содержание
- Installation manual 1
- R22 split series 1
- English 3
- Outline and dimensions 3
- Outline and dimensions 4
- English 5
- Installation manual 6
- Notice 6
- Safety precautions 6
- Warning caution 6
- English 7
- Indoor unit 7
- Installation diagram 7
- Outdoor unit 7
- Installation of the indoor unit 8
- Ceiling concealed drain piping work 9
- English 9
- Caution 10
- Installation of the outdoor unit 10
- All model a b c d 11
- English 11
- Gas pipe size mm in 11
- Installation clearance 11
- Liquid pipe size mm in 11
- Max allowable elevation m 11
- Max allowable length m 11
- Maximum pipe length 11
- Minimum distance mm 300 1000 300 500 11
- Model indoor 11
- Outdoor 11
- Outdoor units must be installed such that there is no short circuit of the hot discharge air or obstruction to smooth air ow select the coolest possible place where intake air should not be hotter than the outside temperature refer to operating range 11
- Refrigerant piping 11
- Remark for fdm60jev1k cooling unit recommended to add 6 kg external accumulator 11
- When the pipe length becomes too long both the capacity and reliability drop as the number of bends increases system piping resistance to the refrigerant ow increases thus lowering the cooling capacity as a result compressor reliability will be affected always choose the shortest path and follow the recommendation as tabulated below 11
- Piping connection to the units 12
- Piping works and flaring technique 12
- Electrical connection 13
- English 13
- English 15
- Charge operation 17
- English 17
- Vacuuming and charging 17
- Vacuuming the piping and the indoor unit 17
- Additional charge 18
- Special precautions when charging unit with scroll compressors 18
- Caution 19
- English 19
- Indicator lights 19
- Operating range 20
- Overall checking 20
- Phase protector optional 20
- Caution 21
- English 21
- Service and maintenance 21
- Troubleshooting 21
Похожие устройства
- Thorvik AIW12717 Инструкция по эксплуатации
- Thorvik AIW12717 Брошюра
- Thorvik AIW12122 Брошюра
- Thorvik AIW12122 Инструкция по эксплуатации
- Thorvik AIW12122 Деталировка
- Thorvik AIW3416M Брошюра
- Thorvik AIW3416M Инструкция по эксплуатации
- Thorvik AIWS125M Брошюра
- Thorvik AIWS125M Инструкция по эксплуатации
- Thorvik AIWS124M Брошюра
- Thorvik AIWS124M Инструкция по эксплуатации
- Thorvik AAG0510 Брошюра
- Thorvik AAG0510 Инструкция по эксплуатации
- Thorvik AOS6105 Брошюра
- Thorvik AOS6105 Инструкция по эксплуатации
- Thorvik ARW1261 Брошюра
- Thorvik ARW1261 Инструкция по эксплуатации
- Thorvik ARW3827 Брошюра
- Thorvik ARW3827 Инструкция по эксплуатации
- Thorvik RAD1018 Брошюра