Daikin RXG25J2V1B [10/14] Standby electricity saving
![Daikin RXG25J2V1B [10/14] Standby electricity saving](/views2/1785819/page10/bga.png)
■English 8
Standby Electricity Saving
The standby electricity saving function turns OFF power supply to the outdoor unit and sets the indoor unit
into standby electricity saving mode, thus educing the power consumption of the air conditioner.
CAUTION
The standby electricity saving function cannot be used for models other than the specified ones.
■ Procedure for turning ON standby electricity saving function
1) Check that the main power supply is turned OFF. Turn it OFF if has
not been turned OFF.
2) Remove the stop valve cover.
3) Disconnect the selective connector for standby electricity saving.
4) Turn ON the main power supply.
CAUTION
1) Before connecting or disconnecting the selective connector for standby electricity saving, make sure that the main power sup-
ply is turned OFF.
2) The selective connector for standby electricity saving is required if an indoor unit other than the above applicable ones is con-
nected.
1
2
3
1
2
3
Standby electricity saving
function OFF.
Standby electricity saving
function ON.
The standby electricity saving function is turned OFF
before shipping.
01_EN_3P203824-7E.fm Page 8 Saturday, October 24, 2009 3:57 PM
Содержание
- Installation manual 1
- Models 1
- R410a split series 1
- Rxg25j2v1b rxg35j2v1b 1
- Umeda center bldg 2 4 12 nakazaki nishi kita ku osaka 530 8323 japan 2
- Caution 3
- English 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Accessories supplied with the outdoor unit 4
- Caution 4
- English 2 4
- Precautions for selecting the location 4
- Caution 5
- English 5
- Outdoor unit installation drawings 5
- Drain work 6
- English 4 6
- Installation guidelines 6
- Installing outdoor unit 6
- Outdoor unit installation 6
- Precautions on installation 6
- Caution 7
- Flaring the pipe end 7
- Outdoor unit installation 7
- Refrigerant piping 7
- Warning 7
- English 6 8
- Purging air and checking gas leakage 8
- Warning 8
- Important information regarding the refrigerant used 9
- Outdoor unit installation 9
- Refilling the refrigerant 9
- Refrigerant piping work 9
- Caution 10
- English 8 10
- Standby electricity saving 10
- The standby electricity saving function turns off power supply to the outdoor unit and sets the indoor unit into standby electricity saving mode thus educing the power consumption of the air conditioner 10
- Caution 11
- English 11
- Facility setting 11
- Facility setting cooling at low outdoor temperature 11
- How to forced cooling operation mode 11
- Pump down operation 11
- Caution 12
- English 10 12
- Good wrong 12
- Warning 12
- Wiring 12
- English 13
- Test items 13
- Test run and final check 13
- Trial operation and testing 13
- P203824 7e m09b216 14
Похожие устройства
- Daikin RXG35J2V1B Инструкция по монтажу
- Daikin RMXS112E8V1B Инструкция по монтажу
- Daikin RMXS140E8V1B Инструкция по монтажу
- Daikin RMXS112E8V1B Сервис мануал
- Daikin RMXS140E8V1B Сервис мануал
- Daikin RMXS160E8V1B Инструкция по монтажу
- Daikin RMXS160E8V1B Сервис мануал
- Daikin RMXS112E7V3B Инструкция по монтажу
- Daikin RMXS112E7V3B Сервис мануал
- Daikin RMXS140E7V3B Инструкция по монтажу
- Daikin RMXS140E7V3B Сервис мануал
- Daikin RMXS160E7V3B Инструкция по монтажу
- Daikin RMXS160E7V3B Сервис мануал
- Daikin RMXS160EV1A Технические данные
- Daikin RMXS112EV1A Технические данные
- Daikin RMXS140EV1A Технические данные
- Daikin FCQ71DV3B Технические данные
- Daikin FCQ71DV3B Инструкция по эксплуатации
- Daikin FCQ71DV3B Инструкция по монтажу
- Daikin FCQ71DV3B Сервис мануал