Daikin RXG25J2V1B [3/14] English
![Daikin RXG25J2V1B [3/14] English](/views2/1785819/page3/bg3.png)
1 ■English
Safety Precautions
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNING
...............Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION...............Failure to follow any of CAUTION may result in grave consequences in some cases.
• The following safety symbols are used throughout this manual:
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions concerning the use
and cleaning of the unit according to the Operation Manual.
Be sure to observe this instruction. Be sure to establish an earth connection. Never attempt.
WARNING
• Installation should be left to the dealer or another professional.
Improper installation may cause water leakage, electrical shock, or fire.
• Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, or fire.
• Be sure to use the supplied or specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
• Install the air conditioner on a solid base that can support the weight of the unit.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
• For wiring, use a cable length enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electric shock or fire.)
• Use the specified types of wires for electrical connections between the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force
on the electrical covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.
• If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the
specified refrigerant (R410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, causing
abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the air conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks, or fire.
CAUTION
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual.
Inadequate piping may cause flooding.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
• Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean.
01_EN_3P203824-7E.fm Page 1 Saturday, October 24, 2009 3:57 PM
Содержание
- Installation manual 1
- Models 1
- R410a split series 1
- Rxg25j2v1b rxg35j2v1b 1
- Umeda center bldg 2 4 12 nakazaki nishi kita ku osaka 530 8323 japan 2
- Caution 3
- English 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Accessories supplied with the outdoor unit 4
- Caution 4
- English 2 4
- Precautions for selecting the location 4
- Caution 5
- English 5
- Outdoor unit installation drawings 5
- Drain work 6
- English 4 6
- Installation guidelines 6
- Installing outdoor unit 6
- Outdoor unit installation 6
- Precautions on installation 6
- Caution 7
- Flaring the pipe end 7
- Outdoor unit installation 7
- Refrigerant piping 7
- Warning 7
- English 6 8
- Purging air and checking gas leakage 8
- Warning 8
- Important information regarding the refrigerant used 9
- Outdoor unit installation 9
- Refilling the refrigerant 9
- Refrigerant piping work 9
- Caution 10
- English 8 10
- Standby electricity saving 10
- The standby electricity saving function turns off power supply to the outdoor unit and sets the indoor unit into standby electricity saving mode thus educing the power consumption of the air conditioner 10
- Caution 11
- English 11
- Facility setting 11
- Facility setting cooling at low outdoor temperature 11
- How to forced cooling operation mode 11
- Pump down operation 11
- Caution 12
- English 10 12
- Good wrong 12
- Warning 12
- Wiring 12
- English 13
- Test items 13
- Test run and final check 13
- Trial operation and testing 13
- P203824 7e m09b216 14
Похожие устройства
- Daikin RXG35J2V1B Инструкция по монтажу
- Daikin RMXS112E8V1B Инструкция по монтажу
- Daikin RMXS140E8V1B Инструкция по монтажу
- Daikin RMXS112E8V1B Сервис мануал
- Daikin RMXS140E8V1B Сервис мануал
- Daikin RMXS160E8V1B Инструкция по монтажу
- Daikin RMXS160E8V1B Сервис мануал
- Daikin RMXS112E7V3B Инструкция по монтажу
- Daikin RMXS112E7V3B Сервис мануал
- Daikin RMXS140E7V3B Инструкция по монтажу
- Daikin RMXS140E7V3B Сервис мануал
- Daikin RMXS160E7V3B Инструкция по монтажу
- Daikin RMXS160E7V3B Сервис мануал
- Daikin RMXS160EV1A Технические данные
- Daikin RMXS112EV1A Технические данные
- Daikin RMXS140EV1A Технические данные
- Daikin FCQ71DV3B Технические данные
- Daikin FCQ71DV3B Инструкция по эксплуатации
- Daikin FCQ71DV3B Инструкция по монтажу
- Daikin FCQ71DV3B Сервис мануал