Daikin EKHWSU180D3V3 [5/24] About this document
![Daikin EKHWSU300D3V3 [5/24] About this document](/views2/1788322/page5/bg5.png)
2 About the documentation
Installation manual
5
EKHWSU150~300D3V3 + EKEXPVES
Domestic hot water tank with option kit for air to water heat pump
system
4P510673-1B – 2018.01
WARNING
▪ ONLY use copper wires.
▪ Make sure the field wiring complies with the applicable
legislation.
▪ All field wiring MUST be performed in accordance with
the wiring diagram supplied with the product.
▪ NEVER squeeze bundled cables and make sure they
do NOT come in contact with the piping and sharp
edges. Make sure no external pressure is applied to the
terminal connections.
▪ Make sure to install earth wiring. Do NOT earth the unit
to a utility pipe, surge absorber, or telephone earth.
Incomplete earth may cause electrical shock.
▪ Make sure to use a dedicated power circuit. NEVER
use a power supply shared by another appliance.
▪ Make sure to install the required fuses or circuit
breakers.
▪ Make sure to install an earth leakage protector. Failure
to do so may cause electric shock or fire.
▪ When installing the earth leakage protector, make sure
it is compatible with the inverter (resistant to high
frequency electric noise) to avoid unnecessary opening
of the earth leakage protector.
NOTICE
Precautions when laying power wiring:
▪ Do NOT connect wiring of different thicknesses to the
power terminal block (slack in the power wiring may
cause abnormal heat).
▪ When connecting wiring which is the same thickness,
do as shown in the figure above.
▪ For wiring, use the designated power wire and connect
firmly, then secure to prevent outside pressure being
exerted on the terminal board.
▪ Use an appropriate screwdriver for tightening the
terminal screws. A screwdriver with a small head will
damage the head and make proper tightening
impossible.
▪ Over-tightening the terminal screws may break them.
WARNING
▪ After finishing the electrical work, confirm that each
electrical component and terminal inside the electrical
components box is connected securely.
▪ Make sure all covers are closed before starting up the
unit.
NOTICE
Only applicable if the power supply is three‑phase, and the
compressor has an ON/OFF starting method.
If there exists the possibility of reversed phase after a
momentary black out and the power goes on and off while
the product is operating, attach a reversed phase
protection circuit locally. Running the product in reversed
phase can break the compressor and other parts.
2 About the documentation
2.1 About this document
Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ Domestic hot water tank installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the domestic hot water tank)
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
Technical engineering data
▪ A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The full set of latest technical data is available on the Daikin
extranet (authentication required).
3 About the box
3.1 Overview: About the box
It contains information about:
▪ Unpacking and handling the units
▪ Removing the accessories from the units
Keep the following in mind:
▪ At delivery, the unit MUST be checked for damage. Any damage
MUST be reported immediately to the carrier's claims agent.
▪ Bring the packed unit as close as possible to its final installation
position to prevent damage during transport.
▪ Prepare the path along which you want to bring the unit inside in
advance.
Содержание
- Domestic hot water tank with option kit for air to 1
- Installation manual 1
- Water heat pump system 1
- 1 04 08 2
- 2 6v 9w 2
- 551 emc 2
- Daikin europe n v 2
- Daikin tcf 34 09 2017 2
- Dekra nb0344 2
- Director 2
- Ehbh 1 da 2 ehbx 1 da 2 2
- Ekhws150d3v3 ekhws180d3v3 ekhws200d3v3 ekhws250d3v3 ekhws300d3v3 ekhwsu150d3v3 ekhwsu180d3v3 ekhwsu200d3v3 ekhwsu250d3v3 ekhwsu300d3v3 2
- Electromagnetic compatibility 2014 30 eu 2
- En60335 2 40 2
- Installation manual 2
- Low voltage 2014 35 eu 2
- Machinery 2006 42 ec 2
- Ostend 2nd of november 2017 2
- P509087 1 2
- Shigeki morita 2
- About the box 5 3
- About the documentation 3
- About the documentation 5 3
- About the units and options 6 3
- Caution 3
- Commissioning 14 3
- Danger 3
- Danger risk of burning 3
- Danger risk of electrocution 3
- Danger risk of explosion 3
- Disposal 17 3
- General safety precautions 3
- General safety precautions 3 3
- Glossary 20 3
- Hand over to the user 14 3
- Indicates a situation that could result in burning because of extreme hot or cold temperatures 3
- Indicates a situation that could result in death or serious injury 3
- Indicates a situation that could result in electrocution 3
- Indicates a situation that could result in equipment or property damage 3
- Indicates a situation that could result in explosion 3
- Indicates a situation that could result in minor or moderate injury 3
- Indicates a situation that results in death or serious injury 3
- Installation 8 3
- Installation manual and the installer reference guide must be performed by an authorised installer 3
- Languages are translations 3
- Maintenance and service 14 3
- Meaning of warnings and symbols 3
- Notice 3
- Preparation 7 3
- Table of contents 3
- Technical data 18 3
- The installation of the system and all activities described in the 3
- The original documentation is written in english all other 3
- The precautions described in this document cover very important 3
- Topics follow them carefully 3
- Troubleshooting 16 3
- Warning 3
- Warning flammable material 3
- Electrical 4
- For the installer 4
- General 4
- General safety precautions 4
- Installation site 4
- About the box 5
- About the documentation 5
- About this document 5
- Overview about the box 5
- A c e b d 6
- About the units and options 6
- Domestic hot water tank 6
- Identification 6
- Identification label domestic hot water tank 6
- Overview about the units and options 6
- To remove the accessories from the domestic hot water tank 6
- To unpack the domestic hot water tank 6
- Installation site requirements of the domestic hot water tank 7
- Overview preparation 7
- Preparation 7
- Preparing the installation site 7
- Preparing water piping 7
- Water circuit requirements 7
- About connecting the water piping 8
- About preparing electrical wiring 8
- Connecting the water piping 8
- Installation 8
- Mounting the domestic hot water tank 8
- Opening the units 8
- Overview installation 8
- Precautions when mounting the indoor unit 8
- Preparing electrical wiring 8
- Safety device requirements 8
- To install the domestic hot water tank 8
- To open the switch box cover of the domestic hot water tank 8
- Installation 9
- Precautions when connecting the water piping 9
- To connect the water piping 9
- Installation 10
- To connect the 3 way valve 10
- To fill the domestic hot water tank 10
- To insulate the water piping 10
- About connecting the electrical wiring 11
- Connecting the electrical wiring 11
- E1 e2 e3 e4 11
- E1 e3 e2 e4 11
- Installation 11
- To connect the electrical wiring on the indoor unit 11
- Installation 12
- To connect the electrical wiring on the outdoor unit 12
- V ac 3 kw 12
- Installation 13
- To connect the electrical wiring on the domestic hot water tank 13
- X8m x1m x4m 13
- Checklist before commissioning 14
- Checklist during commissioning 14
- Commissioning 14
- Finishing the domestic hot water tank installation 14
- Hand over to the user 14
- Maintenance and service 14
- Overview commissioning 14
- To close the domestic hot water tank 14
- Checklist for yearly maintenance of the domestic hot water tank 15
- Maintenance and service 15
- Maintenance safety precautions 15
- Overview maintenance and service 15
- Overview troubleshooting 16
- Precautions when troubleshooting 16
- Solving problems based on symptoms 16
- Symptom continuous water discharge 16
- Symptom intermittent water discharge 16
- Symptom no water flow from hot taps 16
- Symptom the water from the hot taps is cold 16
- Troubleshooting 16
- Disposal 17
- A subset of the latest technical data is available on the regional daikin website publicly accessible the full set of latest technical data is available on the daikin extranet authentication required 18
- Components domestic hot water tank 18
- Components g3 kit 18
- Technical data 18
- 11a 12 13 14a l n x2m 19
- For ehbh x units only 19
- L n x8m 19
- Outlook diagram 19
- Technical data 19
- Wiring diagram domestic hot water tank 19
- 8 l n x2m 20
- Glossary 20
- L n x8m 20
- X8m 3 4 1 2 5 20
Похожие устройства
- Daikin EKHWSU200D3V3 Приложение к руководству для дополнительного оборудования
- Daikin EKHWSU200D3V3 Инструкция по монтажу
- Daikin EKHWSU250D3V3 Приложение к руководству для дополнительного оборудования
- Daikin EKHWSU250D3V3 Инструкция по монтажу
- Daikin EKHWSU300D3V3 Приложение к руководству для дополнительного оборудования
- Daikin EKHWSU300D3V3 Инструкция по монтажу
- Daikin EHVH04S18CB3VF Инструкция по эксплуатации
- Daikin EHVH04S18CB3VF Схема
- Daikin EHVH08S18CB3VF Инструкция по эксплуатации
- Daikin EHVH08S18CB3VF Схема
- Daikin EKMBUHBA6V3 Инструкция по эксплуатации
- Daikin EBHQ006BBV3 Инструкция по эксплуатации
- Daikin EBHQ006BBV3 Приложение к руководству для дополнительного оборудования
- Daikin EBHQ006BBV3 Инструкция по монтажу
- Daikin EBHQ008BBV3 Инструкция по эксплуатации
- Daikin EBHQ008BBV3 Приложение к руководству для дополнительного оборудования
- Daikin EBHQ008BBV3 Инструкция по монтажу
- Foodatlas Постмикс LEF-4\5 Foodatlas Eco Инструкция по эксплуатации
- Foodatlas Постмикс LEF-4\5 Foodatlas Eco Сертификат
- Foodatlas Постмикс LEF-3\5 Foodatlas Eco Инструкция по эксплуатации