Daikin EKHWMXB500CA [20/64] X operation

Daikin EKHWMXB500CA [20/64] X operation
3 x Operation
Operating instructions
20
Daikin Control unit
RoCon mb
008.1446899_00 – 07/2019 – EN
3.5 Special functions
At the "Special Level", different functions (mostly useful func-
tions for the heating expert) can be carried out.
The following special functions are possible:
Manual operation (see chap. 3.5.1).
Displaying messages (see chapter 7)
Reset to factory settings (see chap. 3.6.12)
Detailed explanations of these functions can be found in chap. 6.11.
The calling-up of the special functions does not depend
on the rotary switch setting.
Push the Exit button for at least 5 s.
Menu "Special Level" is displayed.
Use the rotary button to select the program to be started.
Confirm the selection with a brief push of the rotary button.
The selected program starts.
Cancellation and jump back by:
pressing the Exit key again or
touching the rotary button or
selecting another menu using the rotary switch.
3.5.1 Manual operation
Manual operation is used to manually control the Daikin
Altherma M ECH
2
O to a specific feed temperature. Manual oper-
ation should only be used for diagnostic purposes.
With hydraulically controlled priority operation for hot water prep-
aration, it must be ensured that the target feed temperature set in
manual mode is sufficient to achieve the stored target hot water
temperature (parameter [T-DHW Setpoint 1]).
Push the Exit button for at least 5 s.
Menu "Special Level" is displayed.
Use the rotary button to select the "Manual Operation"
program.
Confirm the selection with a brief push of the rotary button.
"Manual Operation" is active.
Use the rotary button to set the target feed temperature.
Do not confirm this setting with the rotary button,
as the program is otherwise ended.
During active manual mode, the storage tank temperature
is permanently regulated to the first target hot water tem-
perature parameter value ([T-DHW Setpoint 1]).
The key lock (if it was activated prior to the start of this
function) is reactivated within 2 s to prevent undesired
cancellation of the function through operation of the
RoCon mb controller.
Cancellation and jump back by:
pressing the Exit key again or
touching the rotary button or
selecting another menu using the rotary switch.
If manual operation is ended, the RoCon mb control unit
automatically switches to "Standby" operating mode.
Manual Operation
Special Level
Attention!
Actual mode:
Special Level
Manual Operation
FA failure
Set Point
Current Value
Fig. 3-12 Symbolic brief instructions for manual operation
3.5.2 3-way switching valves reference travel
The positions of the two 3-way switch valves 3UVB1 and
3UV DHW in the Daikin Altherma M ECH
2
O are controlled con-
tinuously between their two basic settings for optimised energy
utilisation (e.g. heating support function).
To ensure this function, the two 3-way switch valves are always
moved automatically to their basic position (bypass - path AB-A
open) at 11:00 hours.
This function can take up to 5 minutes. It is programmed as
standard and cannot be changed.