not turn on the thermopot when empty. Minimum required
amount of water should not be lower than the lowest mark on
the water level scale.
Note: If the water level is lower than minimum amount, the
protection system preventing waterless operation
activates and the appliance is switched off.
5. Push the lid
(3) (3)
(3) (3)
(3) to close it.
6. Connect the detachable power cable
(15) (15)
(15) (15)
(15) and insert the plug
into a socket with a power supply with voltage that should
comply with the data indicated on the appliance.
7. When first connecting to a power supply, the indicator «Boil»
will light up and the thermopot will immediately start boiling.
Attention: Before the first use of the appliance, boil and
pour out water.
8. Immediately after boiling the thermopot will enter the water tem-
perature maintenance mode. Indicator «Keep warm» will light up.
9. To pour water out of the thermopot, press the button «Unlock»
and release the locking mode (presetting). The symbol «Un-lock»
will show that the locking mode is released. Place a cup under the
water supply port
(10) (10)
(10) (10)
(10) and press the button «Dispense». Re-
lease the button when the cup is full. Ten seconds later the water
dispense mode will be set and the indicator «Unlock» will go out.
10.Water can also be dispensed by using the manual pump
(6).(6).
(6).(6).
(6).
Unlock the pump
(6) (6)
(6) (6)
(6) by moving the manual pump lock lever
(7) (7)
(7) (7)
(7) to «Open». Place a cup under the water supply port
(10)(10)
(10)(10)
(10)
and push the pump button. Release the button when the cup is
filled up. Move the manual pump lock lever
(7) (7)
(7) (7)
(7) to «Lock».
11.To supply water, the «Cup switch»
(9) (9)
(9) (9)
(9) can be used. Press the
valve with a cup and move the cup away when the required
amount of water is dispensed.
12.For water dechlorination, press the button «Boil» for re-boiling.
In this case boiling time will be longer.
«Cooling» function and temperature setting
Your appliance has a temperature setting function. There are 4
temperatures for your selection: 45°C, 65°C, 85°C, 98°C and the
«Cooling» mode. When select the «Cooling» mode, the temperature
of water will go down to the room temperature after boiling.
Advise: The «Cooling» function is energy saving and it is
very convenient for using in summer season.
The default status is 85°C. Press the «Temp Set» button, the
98°C indicator light lit. Press it again, the «Cooling»
indicator
light lit, and next is 45°C, 65°C, finally back to 85°C.
Attention: Keeping pressing 5 seconds, it will be back to
default status again.
Before re-using the appliance, empty the water out — as water
can change its color and odor, and yellow spots could appear on the
heating element.
Attention: To fully pour water out from the bulb, take off
the lid from the appliance and pour out water directly
from the internal bulb.

Содержание

Note If the water level is lower than minimum amount the protection system preventing waterless operation activates and the appliance is switched off 5 Push the lid 3 to close it 6 Connect the detachable power cable 15 and insert the plug into a socket with a power supply with voltage that should comply with the data indicated on the appliance 7 When first connecting to a power supply the indicator Boil will light up and the thermopot will immediately start boiling Attention Before the first useof the appliance boiland pour out water 8 Immediately after boiling the thermopot will enter the water tem perature maintenance mode Indicator Keep warm will light up 9 To pour water out of the thermopot press the button Unlock and release the locking mode presetting The symbol Un lock will show that the locking mode is released Place a cup under the water supply port 10 and press the button Dispense Re lease the button when the cup is full Ten seconds later the water dispense mode will be set and the indicator Unlock will go out 10 Water can also be dispensed by using the manual pump 6 Unlock the pump 6 by moving the manual pump lock lever 7 to Open Place a cup under the water supply port 10 and push the pump button Release the button when the cup is filled up Move the manual pump lock lever 7 to Lock 1 l To supply water the Cup switch 9 can be used Press the valve with a cup and move the cup away when the required amount of water is dispensed 12 For water dechlorination press the button Boil for re boiling In this case boiling time will be longer Cooling function and temperature setting Your appliance has a temperature setting function There are 4 temperatures for your selection 45 C 65 C 85 C 98 C and the Cooling mode When select the Cooling mode the temperature of water will go down to the room temperature after boiling Advise The Cooling function is energy saving and it is very convenient for using in summer season The default status is 85 C Press the Temp Set button the 98 C indicator light lit Press it again the Cooling indicator light lit and next is 45 C 65 C finally back to 85 C Attention Keeping pressing 5 seconds it will be back to default status again Before re using the appliance empty the water out as water can change its color and odor and yellow spots could appear on the heating element Attention To fully pour water out from the bulb take off the lid from the appliance and pour out water directly from the internal bulb 7 ENGLISH not turn on the thermopot when empty Minimum required amount of water should not be lower than the lowest mark on the water level scale