Daikin FWXT20AATV3CL [28/40] Operation
![Daikin FWXT20AATV3CL [28/40] Operation](/views2/1795944/page28/bg1c.png)
28
Key/Display
Operation
Power on/off
By pressing the appropriate key, you can switch the device off (standby) or on. The control panel has its own memory,
therefore no settings will be lost in case of shut-down or power outage. The key is used to activate or deactivate the
unit for short periods.
If you plan to keep the device out of service for a prolonged time, remember to deactivate it by disconnecting the
power or removing the power plug.
Cooling only mode
• When this operating mode is enabled, the device dehumidifies and cools the room.
• The temperature can be set between 16 and 31 °C. If the set temperature is lower than the room temperature,
after three minutes (at the most) the cooler-radiator will start running and the device begins to deliver cold air,
continuing to ventilate the room even if the device reaches the set-point.
Ventilation only mode
When you enable this function, the device enable the fan and does not adjust the temperature or the humidity of the
air in the room. THE MODE allows you to set the fan speed
Heating only mode
• When this operating mode is enabled, the device heats the room.
• You can set the temperature between 16 and 31 °C and if the temperature is higher than room temperature, after
three minutes (at the most) the compressor goes off and the appliance begins to provide heat.
Night comfort key
With the device switched on and the cooling or heating mode selected, pressing this key allows you to perform multiple
functions in order to maximise the quietness of the device, saving on electricity and optimally adjusting the temperature
for night comfort.
In this mode the fan is set to minimum speed.
This function should be activated just before falling asleep.
• In cooling mode, the set temperature is increased by 1 °C after 1 hour and by 1 °C after 2 hours. After the second
hour, the temperature setting is not altered any more and after 6 more hours the device shifts to stand-by.
• In heating mode, the set temperature is decreased by 1 °C after 1 hour and by 1 °C after 2 hours. After the
second hour, the temperature setting is not altered any more and after 6 more hours the device shifts to stand-by.
This function is not available in the dehumidification only, ventilation only and automatic economy mode, and can be
excluded at any time (ideally when you wake up) by pressing the key again.
If you simultaneously set the Timer function, the device switches off after the preset time.
Airflow direction control
By pressing the appropriate key, you can set the constant oscillation of the air flow deflector, in which case the symbol
on the display is on, or lock it in any position.
IMPORTANT: Never force the flow deflector manually to move it. In cooling and dehumidification mode, the flow
deflector’s position is reset every 30 minutes in order to prevent the formation of dew.
Fan speed control
Repeatedly pressing this key will change the speed with the following sequence: Minimum, Medium, Maximum and
Automatic.
The higher the set speed, the higher the device’s performance (but also the louder the noise). If you set the speed to
Automatic (you will notice the 3 speed bars slide on the display), the micro-processor will adjust the speed automatically
(the higher the difference between the room temperature and the set temperature, the higher the speed). The speed is
reduced automatically as the room temperature gradually reaches the set temperature. In dehumidification only mode
and night comfort mode, you cannot adjust the speed, as the unit can work only at low speed.
Содержание
- Installation manual p.1
- Daikin altherma aesthetic feet kit p.1
- Installation and user manual p.1
- Daikin altherma heat pump convector p.1
- We want to thank you for choosing one of our products p.2
- We are confident that you will be happy with your selection because it represents the state of the art in the technology of home climate control p.2
- Symbols p.2
- Safety pictograms p.2
- Editorial pictograms p.2
- Daikin europe n v p.2
- Compliance p.2
- By following the suggestions contained in this manual the product you have purchased will operate without problems giving you optimum room temperatures with minimum energy costs p.2
- General table of contents p.3
- General p.3
- Control panel installation and connection 21 p.3
- Instructions for use with touch screen and remote control 26 p.3
- Instructions for use with remote panel ekwhctrl1 30 p.3
- Installation 9 p.3
- Troubleshooting 39 p.4
- Routine maintenance 36 p.4
- General warnings p.5
- General p.5
- Essential safety rules p.6
- Technical specifications p.7
- Product range p.7
- Filomuro overall dimensions p.8
- Dimensions and weight for transportation p.8
- Installation space p.9
- Unit placement p.9
- Installation procedure p.9
- Installation p.9
- Opening the unit p.10
- Wall installation p.12
- Installation template p.14
- Hydraulic connections p.16
- Connection to the 2 way valve unit with thermoelectric motor ekt2vk0 p.17
- Connection to the 3 way diverter valve unit with thermoelectric motor ekt3vk0 p.17
- Condensate drain pipe assembly p.18
- Condensate drain p.18
- Filling system p.19
- Evacuating the air when filling the system p.19
- Wiring p.20
- Cp presence contact input connection p.21
- Control panel installation and connection p.21
- Connection diagram p.21
- Board connections with touchpad and remote control p.21
- Connection diagram p.22
- Connection for remote control panel p.22
- Fitting the wall mounted remote control panel ekwhctrl1 p.23
- Spring clamps ab and cp connection p.24
- Cp presence contact input connection p.24
- Ekwhctrl1 connections p.25
- You can also select the various functions by pressing on the symbols p.26
- Warnings p.26
- Normally the display shows the operating status see the functional description chapter and any alarms see the alarms display paragraph p.26
- Management of the unit with the touch screen and remote control p.26
- Instructions for use with touch screen and remote control p.26
- Operation p.27
- Main switch on and operation p.27
- Key display p.27
- Inserting the battery p.27
- Functional description p.27
- Airflow direction control p.28
- Ventilation only mode p.28
- Power on off p.28
- Operation p.28
- Night comfort key p.28
- Key display p.28
- Heating only mode p.28
- Fan speed control p.28
- Cooling only mode p.28
- Troubleshooting p.29
- Touch screen display keylock p.29
- Setting the timer function p.29
- Operation p.29
- Operating the unit if the remote control is not available p.29
- Key display p.29
- Alarms display p.29
- Display p.30
- Wall mounted control panel with room probe p.30
- Instructions for use with remote panel ekwhctrl1 p.30
- Keys function p.31
- Heating cooling operating mode set up p.31
- General start up p.31
- Activation p.31
- Temperature selection p.32
- Stand by p.32
- Silent operation p.32
- Night function p.32
- Automatic operation p.32
- Room temperature probe offset adjustment p.33
- Operation at maximum ventilation speed p.33
- Minimum brightness reduction p.33
- Key locking p.33
- Deactivation p.33
- Long term shut down p.34
- Led signals ref a p.34
- Error signals p.34
- Electronic control board p.34
- Error reporting p.35
- Routine maintenance p.36
- Maintenance p.36
- External cleaning p.36
- Extraction of filter cells p.37
- Cleaning the air suction filter p.37
- Suggestions for power saving p.38
- Filter media cleaning p.38
- Troubleshooting table p.39
- Troubleshooting p.39
Похожие устройства
-
Daikin RFWXV20AVEBИнструкция по монтажу -
Daikin RFWXV20AVEBИнструкция по эксплуатации -
Daikin RFWXV20AVEBРуководство по монтажу -
Daikin RFWXV20AVEBРуководство по применению -
Daikin RFWXV15AVEBИнструкция по монтажу -
Daikin RFWXV15AVEBИнструкция по эксплуатации -
Daikin RFWXV15AVEBРуководство по монтажу -
Daikin RFWXV15AVEBРуководство по применению -
Daikin FWXT15AATV3CLИнструкция по эксплуатации -
Daikin FWXT10AATV3CLИнструкция по эксплуатации -
Daikin FWXT20AATV3CИнструкция по эксплуатации -
Daikin FWXT15AATV3CИнструкция по эксплуатации