Daikin EKOMB22AAV1 [42/60] Daikin europe nv 42

Daikin EKOMB28AAV1 [42/60] Daikin europe nv 42
Daikin Europe NV
42
input
activated.
Other setting values do not apply.
d
Minimum rpm hot water
25
25
25
Settings reach 20
E
Min. leaving water temperature at OT
(OpenTherm) or RF thermostat
40
40
40
Settings reach 10
60°C
E.
Reaction OT and RF room thermostat
1
1
1
0= do not respond to hot water request if requested temperature
is lower than the set value par. E
1= respond to hot water request with minimum leaving water
temperature limited to set value par. E
2= respond to hot water request with maximum leaving water
temperature (on/off function)
F
Start rpm CH
70
70
70
Settings reach 50
99% of
the set maximum rpm
(propane=50%)
F.
Start rpm hot water
70
70
70
Settings reach 50
99% of the set maximum rpm
(propane=50%)
h
Max. rpm fan (* 100 rpm)
45
46
46
Settings reach 40
50 (EKOMB22AAV1, EKOMB28AAV1 and
EKOMB33AAV1)
This parameter can be used to set the maximum rpm
n
Regulated temperature during boiler
operation (Ta)
8
0
8
0
8
0
Setting reach 60°C
-
90°C
n.
Hot water temperature at Comfort/Eco
0
0
0
Setting reach: 0 or
40°C
60°C
0= reheating temperature is equal to hot water temperature
O.
Wait time CH request response
0
0
0
Settings reach 0
15 minutes
o
Waiting time CH operation after hot water
operation
0
0
0
Settings reach 0
15 minutes
o.
Number of eco days
3
3
3
Settings reach
0
10
0 = Comfort function controllable by Open Therm room
thermostat
1 – 10 number of eco days
P
Anti
-
recycling time
during CH operation
5
5
5
Minimum switch off time on CH operation
Can be set to 0 - 15 minutes
P.
Reference value hot water
24
30
36
0 =
Flow switch applicable
24 = EKOMB22AAV1
30 = EKOMB28AAV1
36 = EKOMB33AAV1