Daikin EKOMB22AAV1 [54/60] Technical specifications

Daikin EKOMB28AAV1 [54/60] Technical specifications
Daikin Europe NV
54
10 TECHNICAL SPECIFICATIONS
Unit category
C13; C33;
C43; C53; C63; C83:C93
Initial gas pressure
G20: 20 mbar, G31: 30, 37 or 50 mbar, G25: 25 mbar
Suitable for gas
Technical data
EKOMB*AAV1
22
28
33
Domestic water
Nom. load upper value*
kW
6.2
24.6
7.9
31.1
8.0
36.3
Nom. load
lower value*
kW
5.6
22.1
7.1
28.0
7.2
32.7
Nom.
out
put
*
kW
6.1
21.0
6.6
26.2
7.9
31.5
Domestic water threshold
l/min
2
Domestic water quantity 60°C
l/min
6
7.5
9
Domestic water quantity 40°C (mixed)
l/min
10
12.5
15
Domestic water
temperature
°C
60
Effective unit wait time**
sec
<1
Domestic water side pressure difference
kPa
See par. 5.2
CH
Nom. load upper value***
kW
6.2
20.8
7.9
26.3
8.0
30.3
Nom. load lower value***
kW
5.6
18.7
7.1
23.7
7.2
27.3
Nom.
out
put
at 80/60°C***
kW
5.4
17.8
6.9
22.8
7.1
26.3
Nom.
out
put
at 50/30°C***
kW
5.9
18.5
7.6
23.4
7.8
27.1
Max.
CH water pressure
bar
3
Max. CH water temperature
°C
90
Other data
Gas consumption (G25)
m
3
/h
0.67
2.65
0.85
3.36
0.86
3.93
Gas consumption (G20)
m
3
/h
0.58
2.29
0.74
2.91
0.75
3.39
Gas consumption (G31)
m
3
/h
0.22
0.87
0.28
1.11
0.28
1.29
Pressure loss unit (CH)
mWk
See par.
7.4
Electrical data
Mains voltage
V
230
230
230
Safety class
IP
IP44
IP44
IP44
Absorbed power: full load
W
105
105
105
Absorbed power: standby
W
2
2
2
Installation measurements and weight
Height
mm
590
650
710
Width
mm
450
Depth
mm
240
kg
30
33
36
* For 2 minutes, the maximum value, then the base value stated in brackets.
** Time needed from beginning of draining in order to achieve a temperature increase of 40K to the hot water outlet of the device based on the
CH hot water flow.
*** The maximum CH power is set in the factory. For the set value see the parameter list (par. 7.2 ).
Also see par. 7.3 Setting CH power.

Содержание