Daikin EKHBRD011ADY17 [43/48] Domestic water heating

Daikin EKHBRD011ADY17 [43/48] Domestic water heating
EKHBRD011~016ADV17+Y17
Indoor unit for air to water heat pump system
4P402191-1B 2017.09
Installation manual
40
Domestic water heating
Ye s
Normal domestic hot water
operation?
No
Ye s
Storage
operation?
No Forced operation
Automatic?
Storage function Reheat function
Ye s N o
Automatic storage set point [b-02]?
Reheat minimum
temperature [b-00]
Reheat maximum
temperature [b-01]
Disinfection function
[4-00] (default)
Manual storage
function
Ye s N o
Storage set
point [b-03]
Disinfection set point
[5-00]
Automatic
storage set point
[b-02]?
No
Ye s
Automatic daily pre-programmed?
Push button
Disinfection retention
time [5-01] No
Storage set
point [b-03]
Ye s
Automatic storage
function (default)
Schedule storage
function
Reheat enabled,
icon continuous
visible
Day selection [4-01]
Ye s
Sufcient hot water?
Schedule domestic
hot water
Push button (*)
Hour selection [4-02]
Push button
for 5 seconds
No
Active daily day
storage [1-02]
Custom made
domestic hot water
schedule
Reheat disabled
icon not visible
Disinfection function
will operate
depending on
settings request
icon will start
blinking with 0.5
second intervals
Domestic hot
water production
will start
immediately
icon will start
blinking with 1
second intervals
Choose start time
[1-03]
(*) It is not possible to
see when actual
domestic hot water is
made. If you want to
disable reheat
function and at the
same time domestic
hot water is being
produced in reheat
operation, you have to
push 2 times the
button; 1 time to stop
current reheat
domestic hot water
operation and 1 time
to stop reheat enable.
Automatic daily
day storage
Push button Push button
Automatic daily night storage
[1-00] and [1-01]
Current disinfection
operation will stop,
but restart next
scheduled action.
icon will return to
previous state.
Domestic hot
water production
will stop.
icon will return
to previous state.
Push button
icon will appear, domestic hot
water will be produced at next
scheduled action.
When making domestic hot water,
icon will be blinking (1 second
interval)
Push button
Current domestic hot water operation will
stop, but restart next scheduled action.
icon will return to previous state.
Stop
Stop and restart
Enable/disable