Daikin EHYHBX08AFV3 [51/60] Energy saving tips
![Daikin EHYHBX08AFV3 [51/60] Energy saving tips](/views2/1798412/page51/bg33.png)
7 | Energy saving tips
User reference guide
51
EHYHBH05AF + EHYHBH/X05+08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355632-1E – 2020.10
7 Energy saving tips
Tips about room temperature
▪ Make sure the desired room temperature is NEVER too high (in heating mode) or
too low (in cooling mode), but ALWAYS according to your actual needs. Each
saved degree can save up to 6% of heating/cooling costs.
▪ Do NOT increase/decrease the desired room temperature to speed up space
heating/cooling. The space will NOT heat up/cool down faster.
▪ When your system layout contains slow heat emitters (example: underfloor
heating), avoid large fluctuation of the desired room temperature and do NOT let
the room temperature drop too low/rise too high. It will take more time and
energy to heat up/cool down the room again.
▪ Use a weekly schedule for your normal space heating or cooling needs. If
necessary, you can easily deviate from the schedule:
- For shorter periods: You can overrule the scheduled room temperature.
Example: When you have a party, or when you are leaving for a couple of
hours.
- For longer periods: You can use the holiday mode. Example: When you stay at
home during your holiday, or when you go away during your holiday.
Tips about leaving water temperature
▪ In heating mode, a lower desired leaving water temperature results in lower
energy consumption and better performance. In cooling, the opposite is valid.
▪ Set the desired leaving water temperature in accordance with the heat emitter
type. Example: Underfloor heating is designed for lower leaving water
temperature than radiators and heatpump convectors.
Tips about DHWtank temperature
▪ Use a weekly schedule for your normal domestic hot water needs (only in
scheduled mode).
- Program to heat up the DHW tank to a preset value (Storage comfort =
higher DHW tank temperature) during the night, because then space heating
demand is lower.
- If heating up the DHW tank once at night is not sufficient, program to
additionally heat up the DHWtank to a preset value (Storage eco = lower
DHWtank temperature) during the day.
▪ Make sure the desired DHWtank temperature is NOT too high. Example: After
installation, lower the DHWtank temperature daily by 1°C and check if you still
have enough hot water.
▪ Program to turn ON the domestic hot water pump only during periods of the day
when instant hot water is necessary. Example: In the morning and evening.
Содержание
- Daikin altherma hybrid heat pump 1
- User reference guide 1
- About the system 8 2
- About this document 7 2
- General safety precautions 4 2
- Operation 9 2
- Setting the energy prices 47 2
- Table of contents 2
- User reference guide 2
- Disposal 57 3
- Energy saving tips 51 3
- Energy visualisation 50 3
- Glossary 58 3
- Maintenance and service 52 3
- Relocation 56 3
- Table of contents 3
- Troubleshooting 53 3
- About the documentation 4
- General safety precautions 4
- Meaning of warnings and symbols 4
- For the user 5
- General safety precautions 5
- Warning if you are not sure how to operate the unit contact your installer 5
- Warning this appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved children shall not play with the appliance cleaning and user maintenance shall not be made by children without supervision 5
- Caution do not place any objects or equipment on top of the 6
- Do not sit climb or stand on the unit 6
- General safety precautions 6
- Warning to prevent electrical shocks or fire do not rinse the unit do not operate the unit with wet hands do not place any objects containing water on the unit 6
- About this document 7
- About the system 8
- Components in a typical system layout 8
- Operation 9
- Overview operation 9
- Buttons 10
- Operation 10
- The user interface at a glance 10
- Operation 11
- Status icons 11
- Basic usage 12
- Operation 12
- Using home pages 12
- Using the menu structure 12
- Operation 13
- Turning on off controls 13
- About space heating cooling control 14
- Operation 14
- Setting the space operation mode 14
- Space heating cooling control 14
- Operation 15
- Determining which temperature control you are using 16
- Operation 16
- Operation 17
- Room thermostat control about room thermostat control 17
- Operation 18
- Room thermostat control using the room temperature home pages 18
- Operation 19
- Operation 20
- Operation 21
- Operation 22
- Room thermostat control using the leaving water temperature home pages 22
- C 37 c 23
- C 47 c 23
- Operation 23
- C 47 c 24
- Leaving water temperature control about leaving water temperature control 24
- Operation 24
- A schedule 25
- According to a schedule 25
- C 37 c 25
- C 47 c 25
- External room thermostat control about external room thermostat control 25
- Leaving water temperature control using leaving water temperature control according to 25
- Leaving water temperature control using leaving water temperature control not 25
- Operation 25
- About domestic hot water control 26
- C 37 c 26
- C 47 c 26
- Domestic hot water control 26
- External room thermostat control using external room thermostat control 26
- Instant dhw no tank installed 26
- Operation 26
- Operation 27
- Operation 28
- Operation 29
- Operation 30
- About changing the user permission level 31
- Advanced usage 31
- Operation 31
- Using quiet mode 31
- Operation 32
- Using holiday mode 32
- Holiday 33
- Operation 33
- Operation 34
- Operation 35
- Reading out information 35
- Configuring date time units of measurement contrast and backlight 36
- Configuring user profile and home pages 36
- Operation 36
- Locking and unlocking buttons and functions 37
- Operation 37
- Operation 38
- Preset values and schedules 38
- Using preset values 38
- Operation 39
- Using and programming schedules 39
- Operation 40
- Schedules example 40
- Operation 41
- Predefined schedules room temperature leaving water temperature main 41
- Operation 42
- Predefined schedules dhw tank temperature 42
- Predefined schedules leaving water temperature additional 42
- Operation 43
- To set the weather dependent settings 43
- Weather dependent operation 43
- Menu structure overview user settings 44
- Operation 44
- Installer settings tables to be filled in by installer 45
- Operation 45
- Quick wizard 45
- Contact helpdesk number 6 46
- Domestic hot water control a 46
- Operation 46
- Space heating cooling control 46
- Setting the energy prices 47
- To set the electricity price 47
- To set the gas price 47
- About energy prices in case of an incentive per kwh renewable 48
- Energy 48
- Example 48
- Setting the energy prices 48
- To set the electricity price in case of an incentive per kwh renewable energy 48
- To set the electricity price schedule timer 48
- To set the gas price in case of an incentive per kwh renewable energy 48
- Setting the energy prices 49
- Energy visualisation 50
- To view the energy statistics 50
- Energy saving tips 51
- Maintenance and service 52
- Overview maintenance and service 52
- To find the contact helpdesk number 52
- Overview troubleshooting 53
- Symptom you are feeling too cold hot in your living room 53
- To check the error history 53
- To check the warning history 53
- Troubleshooting 53
- Symptom heat pump failure 54
- Symptom the water at the tap is too cold 54
- Troubleshooting 54
- Troubleshooting 55
- Overview relocation 56
- Relocation 56
- Disposal 57
- Notice 57
- Glossary 58
Похожие устройства
- Daikin EHYHBX08AFV3 Руководство по применению для установщика
- Daikin EHYKOMB33AA Инструкция по эксплуатации
- Daikin EHYKOMB33AA2A Руководство по эксплуатации
- Daikin EHYKOMB33AA2A Руководство по применению для установщика
- Daikin EHYKOMB33AA2A Справочное руководство для монтажника
- Daikin EHYKOMB33AA2 Руководство по эксплуатации
- Daikin EHYKOMB33AA2 Справочное руководство для монтажника
- Daikin EHYKOMB33AA2 Руководство по применению для установщика
- Daikin EHYKOMB33AA3 Руководство по эксплуатации
- Daikin EHYKOMB33AA3 Руководство по применению для установщика
- Daikin EHYKOMB33AA3 Справочное руководство для монтажника
- Daikin EKBALLV1 Инструкция по монтажу
- Daikin EKBPHT04JH Инструкция по монтажу
- Daikin EKDPH008C Инструкция по монтажу
- Daikin EKEPHYHT35H Инструкция по монтажу
- Daikin EKHY3PART Инструкция по монтажу
- Daikin EKHY075787 Инструкция по монтажу
- Daikin EKHY075787 Брошюра
- Daikin EKPS075867 Инструкция по монтажу
- Daikin EKPS075867 Брошюра