Daikin EHYKOMB33AA2 — руководство по устранению неполадок для тепловых насосов [82/108]

Превью страниц Страница 82 / 108
Daikin EHYKOMB33AA2 [82/108] Troubleshooting
13 Troubleshooting
Installer reference guide
82
CHYHBH05+08AA + EHYKOMB33A
Daikin hybrid for multi heat pump – heat pump module
4P471761-1A – 2017.10
Error code Detailed error
code
Description
89 02 Heat exchanger frozen.
89 03 Heat exchanger frozen.
8F 00 Abnormal increase outlet
water temperature (DHW).
8H 00 Abnormal increase outlet
water temperature.
8H 03 Overheating water circuit
(thermostat).
A1 00 Zero cross detection problem.
Power reset required.
Please contact your dealer.
A1 01 EEPROM reading error.
AA 01 Backup heater overheated.
Power reset required.
Please contact your dealer.
AH 00 Tank disinfection function not
completed correctly.
AJ 03 Too long DHW heat-up time
required.
C0 00 Flow sensor/switch malfunction.
Please contact your dealer.
C4 00 Heat exchanger temperature
sensor problem.
Please contact your dealer.
CJ 02 Room temperature sensor
problem.
Please contact your dealer.
EC 00 Abnormal increase tank
temperature.
EC 04 Tank preheating
H1 00 External temperature
sensor problem.
Please contact your dealer.
Error code Detailed error
code
Description
HC 00 Tank temperature sensor
problem.
Please contact your dealer.
HJ 11 Boiler abnormality detection
Check boiler
Refer to boiler manual
HJ 12 Bypass valve turning error
Please contact your dealer.
U3 00 Under floor heating screed
dryout function not completed
correctly.
U4 00 Indoor/outdoor unit
communication problem.
U5 00 User interface
communication problem.
U6 36 Boiler standby abnormality
Check boiler
Refer to boiler manual
U8 01 Connection with adapter lost
Please contact your dealer.
UA 00 Indoor unit, outdoor unit
matching problem.
Power reset required.
UA 52 Boiler, indoor unit matching
problem.
Please contact your dealer.
INFORMATION
In case of error code AH and no interruption of the
disinfection function occurred due to domestic hot water
tapping, following actions are recommended:
When the Domestic hot water > Type > Reheat or
Reheat + sched. is selected, it is recommended to
program the start-up of the disinfection function at least
4 hours later than the last expected large hot water
tapping. This start-up can be set by installer settings
(disinfection function).
When the Domestic hot water > Type > Scheduled only
is selected, it is recommended to program a Storage
eco 3 hours before the scheduled start-up of the
disinfection function to preheat the tank.
NOTICE
When the minimum water flow is lower than described in
the table below, the unit will temporarily stop operation and
the user interface will display error 7H‑01. After some time,
this error will reset automatically and the unit will resume
operation.
Minimum required flow during heat pump operation
05+08 models 9l/min