Daikin EKPS076197 [162/216] Options

Daikin EKPS076207 [162/216] Options
162
Accessories Order No.
Condensate box
Not needed in all cases. Depends on local regulation and used oil
type. Based on that free decision who will use. Option, but will fit
inside the unit
DRCONDENBOXA
Material refill: Granulate DRCONDENREFA
Oil-bleeder TOP 2
With integrated filter (multiple filter) and block valve. Working
overpressure max 0,7 bar, filter 20-35 μm, return flow max. 120 l/h
15 60 79
Pump group
For a mixed and unmixed heating circuit. Pre-assembled, leakage
tested and thermally insulated assembly group. Incl. temperature
indicator and arrangeable gravity brake. With Grundfoss pump UPM
3 Hybrid 25 - 70/80. Pin G1, without PWM-cable
Pump group with mixer (DRMPUMPGURPAA)
Pump group without mixer (DRUPUMPGURPAA)
15 60 75
15 60 77
Screwing set for the pump group 1 " IG x 1 1 / 2 " flat sealing 15 60 53
Heating circuit distributor 2-fold
with integrated hydraulic diverter
A distributor which combines the function of a hydraulic diverter
and a distributor. Applied in heating and air-conditioning systems,
it enables the regulation of different lines. Separate lateral
connections, incl. wall bracket and performed sound insulation.
Combinable with pump group 15 60 75 or 15 60 77
15 60 78
Hydraulic separator HW2500
Low loss header HW2500 with performed insulation and drain
valve, for vertical installation, input/output G1 IG (DN 25),
withunion nut, flow-rate up to 2,500 l
Function:
- Hydraulic separation
- Ventilation
- Sludge separation
- Detachement of magnetic particles
15 60 25
Sludge and magnetite separator
SAS2
Compact sludge separator with drain cock and thermal insulation.
Input G1-IG
15 60 23
Hydraulic diverter HWC - DN 125
for up to 3 heat generators
Consisting of DN 125 round pipe sub-divided into four zones (using
perforated separator discs, length approx. 1,550 mm), equipped
with 8 x heating circuit connections 1“ male thread, and a 1 x 1/2“
sleeve and standing foot. Max. permissible operating pressure: 6
bar, max. permissible temperature: 110 °C
17 29 00
Thermal insulation WHWC for
hydraulic diverter
Thermal insulation in accordance with EnEV, consisting of 60 mm
PUR foam in a galvanised sheet steel casing
17 29 01
VA-Oil feeding line
PEX-AL compound pipe as oil supply line approved by the building
supervision authorities in the DIBT test. Test mark of the building
supervision authority: Z-40.23-331. Thick-walled PEX inner piper
with butt-welded alumninium covering and silver-grey PE-external
layer. Due to the aluminium covering 100% diffusion tightness.
Neutral to heating oil, prevents degradation in the heating oil. Type
of delivery: Ring coil packaged in box
VA Oil pipe
Ø 12 x 3 60 m 17 06 31
Screw connection VA-Oil
To connect the oil feed pipe VA-oil to the extraction armature and
to the oil filter. Clamping ring screwed fitting made of brass or parts
in contact with oil made of stainless steel. Suitable for VA-Oil pipe
Ø 12 x 3, connecting thread 3 / 8“ male thread. Test mark of the
building supervision authority: Z-40.23-331
Screw connection VA-Oil
10 pc. 17 80 13
Connect VA-Oil
10 m PEX-AL compound pipe as an oil-conveying line with two
screwed connection fittings 12 x 3 - 3 / 8“ male thread
10 m 17 06 32
Options