Operation manual
2
• After reading, keep this manual in a conve-
nient place so that you can refer to it when-
ever necessary. If the equipment is
transferred to a new user, be sure also to
hand over the manual.
WARNING
Be aware that prolonged, direct exposure to
cool or warm air from the air conditioner, or
to air that is too cool or too warm can be
harmful to your physical condition and
health.
When the CONVENI-PACK is malfunctioning
(giving off a burning odour, etc.) turn off
power to the unit and contact your local
dealer.
Continued operation under such circumstances
may result in a failure, electric shocks or fire haz-
ards.
Consult your local dealer about installation
work.
Doing the work yourself may result in water leak-
age, electric shocks or fire hazards.
Consult your local dealer regarding modifica-
tion, repair and maintenance of the CONVENI-
PACK.
Improper workmanship may result in water leak-
age, electric shocks or fire hazards.
Do not place objects, including rods, your fin-
gers, etc., in the air inlet or outlet.
Injury may result due to contact with the CON-
VENI-PACK’s high-speed fan blades.
Never touch the air outlet or the horizontal
blades while the swing flap is in operation.
Fingers may become caught or the unit may
break down.
Beware of fire in case of refrigerant leakage.
If the CONVENI-PACK is not operating correctly
(i.e. the interior temperature of the CONVENI-
PACK does not drop efficiently), refrigerant leak-
age could be the cause.
Consult your dealer for assistance.
The refrigerant within the CONVENI-PACK is
safe and normally does not leak.
However, in the event of a leakage, contact with a
naked burner, heater or cooker may result in gen-
eration of noxious gas.
Do not longer use the CONVENI-PACK until a
qualified service person confirms that the leak-
age has been repaired.
Consult your local dealer regarding what to
do in case of refrigerant leakage.
When the CONVENI-PACK is to be installed in a
small room, it is necessary to take proper mea-
sures so that the amount of any leaked refriger-
ant does not exceed the concentration limit in the
event of a leakage. Otherwise, this may lead to
an accident due to oxygen depletion.
Contact professional personnel about attach-
ment of accessories and be sure to use only
accessories specified by the manufacturer.
If a defect results from your own workmanship, it
may result in water leaks, electric shock or fire.
Consult your local dealer regarding reloca-
tion and reinstallation of the CONVENI-PACK.
Improper installation work may result in leakage,
electric shocks or fire hazards.
Do not replace fuses.
Do not use improper fuses, copper or other wires
as a substitute, as this may result in electric shock,
fire, injury or damage to the unit.
Be sure to earth the unit.
Do not earth the unit to a utility pipe, lightning
conductor or telephone earth lead. Imperfect
earthing may result in electric shocks or fire.
A high surge current from lightning or other sources
may cause damage to the CONVENI-PACK.
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may
result in electric shocks or fire.
Consult the dealer if the CONVENI-PACK sub-
merges owing to a natural disaster, such as a
flood or typhoon.
Do not operate the CONVENI-PACK in that case,
or otherwise a malfunction, electric shock, or fire
may result.
Do not start or stop operating the CONVENI-
PACK with the power supply breaker turned ON
or OFF.
Otherwise, fire or water leakage may result. Fur-
thermore, because power failure compensation
is set, the fan will rotate abruptly, which may
result in injury.
Do not use the product in the atmosphere con-
taminated with oil vapor, such as cooking oil or
machine oil vapor.
Oil vapor may cause crack damage, electric
shocks, or fire.
Do not use the product in places with excessive
oily smoke, such as cooking rooms, or in
places with flammable gas, corrosive gas, or
metal dust.
Using the product in such places may cause fire
or product failures.
Do not use flammable materials (e.g., hairspray
or insecticide) near the product.
Do not clean the product with organic sol-
vents such as paint thinner.
The use of organic solvents may cause crack
damage to the product, electric shocks, or fire.
Do not keep in the unit anything volatile or flam-
mable.
Doing so may result in explosion or fire.
Be sure to use a dedicated power supply for the
CONVENI-PACK.
The use of any other power supply may cause
heat generation, fire, or product failures.
4PEN448940-1A.book Page 2 Thursday, August 25, 2016 11:23 AM
Содержание
- Conveni pack 1
- Operation manual 1
- Contents 2
- Safety precautions 2
- This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given super vision or instruction concerning use of the appliance in a safe way and under stand the hazards involved children shall not play with the appliance cleaning and user maintenance shall only be done by persons described in manual 2
- This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commer cial and household use by lay persons 2
- 1 in the case of lryeq16a7y1 5
- 2 in the case of lcbkq3av1 e 5
- Electrical work 5
- In the case of lryeq16a7y1 5
- Name of part 5
- There is a possibility that periodic inspec tions for refrigerant leakage are sched uled consult your local dealer for more information installation site 5
- Operation 6
- Remote controller and cool heat selector name and function of each switch and display 6
- What to do before 6
- What to do before operation 6
- 1 cooling heating automatic and 7
- 1 cooling heating automatic and fan only operation 7
- Fan only operation 7
- Operation procedure 7
- 2 program dry operation 8
- 3 adjusting the air flow direc 9
- 3 adjusting the air flow direction only for double flow multi flow ceiling suspended 9
- Tion only for double flow multi flow ceiling suspended 9
- 4 programming start and stop of 10
- 4 programming start and stop of the system with timer 10
- 5 precautions for group con 10
- 5 precautions for group control system or two remote controller control system 10
- Optimum operation 10
- The system with timer 10
- Trol system or two remote controller control system 10
- 1 the following cases are not malfunc 11
- 1 the following cases are not malfunctions 11
- Care and cleaning method 11
- Troubleshooting 11
- 2 check before requesting servicing 13
- 3 consult your dealer in the following 14
- 3 consult your dealer in the following cases 14
- Inspection 14
- 1 models and main specifications 15
- 1models and main specifications 15
- Booster unit evaporating temperature 35 c outdoor temperature 32 c suction sh 10 c saturated temperature to discharge pressure of booster unit 10 c 15
- Height of 1 m values measured with the models actually installed are usually larger then the values shown as a result of ambient noise and reflections when the outdoor temperature is low the temperature reading may be below the target evaporating tem perature set for the protection of the unit 15
- Note operating conditions 15
- Outdoor unit air conditioning side indoor temperature 27 cdb 19 cwb outdoor temperature 32 cdb piping length 7 m level difference 0m in cooling priority mode cooling equipment side evaporating temperature 10 c outdoor temperature 32 cdb suction sh 10 c in cooling priority mode heating conditions indoor temperature 20 cdb outdoor temperature 7 cdb 6 cwb cooling equip ment load 18 kw piping length 7 m level difference 0 m saturated temperature equivalent to suction pressure cooling equipment side 10 c under chilled condition connection capacity for indoor air conditioner 10hp when heat recovery is 100 sound pressure level is less than 70 db a 15
- Product models and main specifications 15
- The figures for the outside unit models show values measured at a distance of 1 m in the front and a 15
- Values are subject to change without notice for product improvements the e suffix indicates anti corrosion models 15
- 1 after sale service 16
- 2 1 accidents resulting from use 16
- 2 2 selection installation work failures 16
- 2 onerous repairs outside scope 16
- 2 onerous repairs outside scope of warranty coverage 16
- After sale service and 16
- After sale service and warranty 16
- Beyond standards for use 16
- Of warranty coverage 16
- Specified below and other failures 16
- Warranty 16
Похожие устройства
- Daikin LRYEQ16A7Y1 Брошюра
- Daikin LRLEQ3BY1 Технические данные
- Daikin LRLEQ3BY1 Общие правила техники безопасности
- Daikin LRLEQ3BY1 Инструкция по эксплуатации
- Daikin LRLEQ3BY1 Руководство по применению для установщика
- Daikin LRLEQ4BY1 Технические данные
- Daikin LRLEQ4BY1 Общие правила техники безопасности
- Daikin LRLEQ4BY1 Инструкция по эксплуатации
- Daikin LRLEQ4BY1 Руководство по применению для установщика
- Daikin LRLEQ5AY1 Справочное руководство для монтажника
- Daikin LRLEQ5AY1 Сервис мануал
- Daikin LRLEQ5AY1 Инструкция по эксплуатации
- Daikin LRLEQ5AY1 Инструкция по монтажу
- Daikin LRLEQ5AY1E Справочное руководство для монтажника
- Daikin LRLEQ5AY1E Сервис мануал
- Daikin LRLEQ5AY1E Инструкция по эксплуатации
- Daikin LRLEQ5AY1E Инструкция по монтажу
- Daikin LRLEQ6AY1 Справочное руководство для монтажника
- Daikin LRLEQ6AY1 Сервис мануал
- Daikin LRLEQ6AY1 Инструкция по эксплуатации