Haier HSU-12H03/R(QXF) [14/109] Functions and control
![Haier HSU-09H03/R(QXF) [14/109] Functions and control](/views2/1809716/page14/bge.png)
HSU-09/12H03/R(QXF) Functions and control
11
Domestic Air Conditioner
5ˊFunctions and control
5.1 main functions and control specifications
Including brief introduction to air conditioners of series models and electric control function.
Automatic running
Indoor
temperature
control
Dehumidification
running
When the system runs under "automatic" mode for the first time, it will determine the
operating mode according to the follows,
TrTs-3 Choose Cooling Modeć
Tr˘Ts-3ć Choose Heating Mode
The system will shift its operating mode between the above mentioned two to changes of
the indoor temperature. If the system is currently under cooling mode, the compressor
will stop functioning if the temperature lowers to such a degree that requires so; then it
will recheck the temperature 15 minutes later: it will switch to the heating mode if the
temperature is Tr˘Ts-3 ,or it will still stay in cooling mode(including blowing mode). if ć
the system is currently under heating mode, the compressor will stop running if the
temperature lowers to such a degree that requires so, then it will recheck the
temperature 15 minutes later: it will switch to the cooling mode if the temperature is Tr
˚Ts+3 .ć
Temperature control range : 16ć—30ć
Temperature control precision: ±1ć
Compressor can’t be controlled by temperature sensor within 2 minutes after it starts
ķ Cooling mode:
When Tr> Ts, outdoor fan motor and compressor on, and indoor fan motor run at fixed
wind speed. When Tr < Ts, outdoor fan motor and compressor off, and when Tr > Ts,
outdoor fan motor and compressor are working again .If Tr=Ts, the indoor fan motor ,
outdoor fan motor and the compressor’s state will not change.
ĸ Heating mode:
When Tr ≤ Ts, compressor, four-ways valve and outdoor fan motor is on, indoor fan
motor runs as in cold blast avoidance mode, and 4ćof compensation is added after
compressor is started.
When Tr>Ts+5ć, compressor is off, and the indoor fan motor runs as in cold blast
avoidance mode.
When Tr<Ts+5ć, compressor, four-ways valve and outdoor fan motor is on, and the
indoor fan motor runs as in the mode of avoiding cold blast.
The compressor, outdoor fan and indoor fan will run as per the following
working pattern so as to realize the refrigerating running of dehumidification:
ķ Tr> Ts+2 , compressor, outdoor fan run continuously, indoor fan runs as per setting ć
wind speed (State 1);
ĸ Ts+2 TrTs, compressor, outdoor fan run intermittently with 10ć
minutes ON, 6 minutes OFF. (Compressor and outdoor fan are synchronous)
indoor fan runs in fixed lower wind speed, and will cease at the stand-by time of
3 minutes (State 2)
Ĺ
Tr <Ts, compressor, outdoor fan ceases, indoor fan runs in lower wind
speed. (State 3)
Содержание
- Caution in repair 4
- Introduction 4
- Safety cautions 4
- Warning 4
- Cautions regarding products after repair 5
- Domestic air conditioner 5
- Hsu 09 12h03 r qxf introduction 5
- Warning 5
- Caution 6
- Domestic air conditioner 6
- Hsu 09 12h03 r qxf introduction 6
- Warning 6
- Caution 7
- Domestic air conditioner 7
- Hsu 09 12h03 r qxf introduction 7
- Inspection after repair 7
- Warning 7
- Domestic air conditioner 8
- Hsu 09 12h03 r qxf introduction 8
- Icon type of information description 8
- Icons are used to attract the attention of the reader to specific information the meaning of each icon is described in 8
- The table below 8
- Using icons 8
- Using icons list 8
- Functions and control 14
- Main functions and control specifications 14
- Minutes 16
- Hours t 1 hour ts 2 ts 1 1 hours 17
- Off t hour 17
- T ts 3hours 3hours ts 2 ts 3 ts 4 1 hour 17
- Timer function 18
- Function of main thermistor 19
- B25 50 4200k 3 20
- Domestic air conditioner 20
- Indoor unit 20
- R25 23k 3 20
- Room sensor 20
- Value of thermistor 20
- Domestic air conditioner 21
- Hsu 09 12h03 r qxf funtions and control 21
- Domestic air conditioner 22
- Hsu 09 12h03 r qxf funtions and control 22
- Domestic air conditioner 23
- Hsu 09 12h03 r qxf funtions and control 23
- B25 50 3700k 3 24
- Domestic air conditioner 24
- Hsu 09 12h03 r qxf funtions and control 24
- Pipe sensor 24
- R25 10k 3 24
- Domestic air conditioner 25
- Hsu 09 12h03 r qxf funtions and control 25
- Domestic air conditioner 26
- Hsu 09 12h03 r qxf funtions and control 26
- Domestic air conditioner 27
- Hsu 09 12h03 r qxf funtions and control 27
- System configuration 28
- Cautions 29
- Contain no fluorochloric hydrocarbon 29
- Disposal of the old air conditioner 29
- Disposal of the packaging of your new air conditioner 29
- Instruction 29
- Safety instructions and warnings 29
- Cautions 30
- Specifications 30
- The machine is adaptive in following situation 30
- Caution 31
- Cautions 31
- Installation 31
- Safety instruction 31
- Warning 31
- Caution 32
- Cautions 32
- Domestic air conditioner 32
- Hsu 09 12h03 r qxf system configuration 32
- Warning 32
- Indoor unit 33
- Outdoor unit 33
- Parts and functions 33
- Emergency and test operation 46
- Emergency operation 46
- Operation 46
- Removal of the restriction of emergency or test operation 46
- Test operation 46
- For smart use of the air conditioner 47
- Maintenance 47
- Air filter cleaning 48
- Attach the filter 48
- Clean the filter 48
- Close the inlet grille 48
- Do not use the following for cleaning 48
- For smart use of the air conditioner 48
- Indoor body 48
- Maintenance 48
- Open the inlet grille by pulling it upward 48
- Remote controller 48
- Remove the filter 48
- Warning 48
- Maintenance 50
- To keep your air conditioner in good condition after season 50
- Before setting in high season 51
- Caution 51
- Cleaning the standard air filter 51
- Connecting the earthing cable 51
- Do not block the air inlet or outlet 51
- Earthing 51
- Maintenance 51
- No wet hand 51
- Plug in 51
- Before asking for service check the following first 52
- Trouble shooting 52
- Fresh air pipe 1 full energy recovery exchanger 66
- Packing list 66
- Refresh system installation 66
- Bend connector 67
- Full energy recovery exchanger 67
- Room air pipe 67
- According to the drawing install the full energy recovery exchanger on 68
- Installation manual 68
- Outdoor unit cover with the screws 68
- The corresponding place of the outdoor unit and fix the fittings on the 68
- The main unit installation 68
- Pipeline installation 69
- Small size outdoor unit installation sketch 69
- Caution 70
- Power block installation 70
- Indoor unit 71
- Installation of indoor unit 71
- 5 drain pan 81
- 0 outdoor panel 94
- Appendix 104
- Cooling 104
- Heating 104
- Hsu 09 12h03 r qxf appendix 104
- Piping diagrams 104
- Hsu 09 12h03 r qxf appendix 105
- Indoor 105
- Wiring diagrams 105
- Circuit diagram 107
- Circuit diagram 1 107
- Circuit diagram 2 108
- Hsu 09 12h03 r qxf appendix 108
Похожие устройства
- Sc&t HKM02BT Инструкция по эксплуатации
- Sc&t HKM02BR Инструкция по эксплуатации
- Sc&t HKM02BT-4K Инструкция по эксплуатации
- Sc&t HKM02BR-4K Инструкция по эксплуатации
- Sc&t HKM02BPT-4K Инструкция по эксплуатации
- Sc&t HKM02BPR-4K Инструкция по эксплуатации
- Sc&t HE01SER Инструкция по эксплуатации
- Sc&t HE01ERK Инструкция по эксплуатации
- Sc&t HE01ST Инструкция по эксплуатации
- Sc&t HE01SR Инструкция по эксплуатации
- Sc&t HW01 Инструкция по эксплуатации
- Sc&t HE01SI Инструкция по эксплуатации
- Sc&t HE01S Инструкция по эксплуатации
- Sc&t HKM01E Инструкция по эксплуатации
- Sc&t HE03 Инструкция по эксплуатации
- Sc&t HE02EI Инструкция по эксплуатации
- Sc&t HE02EIP Инструкция по эксплуатации
- Sc&t HE02EIX Инструкция по эксплуатации
- Sc&t HE02E Инструкция по эксплуатации
- Sc&t HE02 Инструкция по эксплуатации