HSU-09,12H03/R(QXF) Introduction
3
Domestic Air Conditioner
Warning
Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to
the electrical equipment, the internal wiring regulations and the instruction manual for installation when
conducting electrical work.
Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire.
Be sure to use the specified cable to connect between the indoor and outdoor units. Make the
connections securely and route the cable properly so that there is no force pulling the cable at the
connection terminals.
Improper connections can cause excessive heat generation or fire.
When connecting the cable between the indoor and outdoor units, make sure that the terminal cover does
not lift off or dismount because of the cable.
If the cover is not mounted properly, the terminal connection section can cause an electrical shock,
excessive heat generation or fire.
Do not damage or modify the power cable.
Damaged or modified power cable can cause an electrical shock or fire. Placing heavy items on the
power cable, and heating or pulling the power cable can damage the cable.
Do not mix air or gas other than the specified refrigerant (R-410A / R22) in the refrigerant system.
If air enters the refrigerating system, an excessively high pressure results, causing equipment damage
and injury.
If the refrigerant gas leaks, be sure to locate the leak and repair it before charging the refrigerant. After
charging refrigerant, make sure that there is no refrigerant leak.
If the leak cannot be located and the repair work must be stopped, be sure to perform pump-down and
close the service valve, to prevent the refrigerant gas from leaking into the room. The refrigerant gas itself
is harmless, but it can generate toxic gases when it contacts flames, such as fan and other heaters,
stoves and ranges.
When replacing the coin battery in the remote controller, be sure to disposed of the old battery to prevent
children from swallowing it.
If a child swallows the coin battery, see a doctor immediately.
Caution
Installation of a leakage breaker is necessary in some cases depending on the conditions of the
installation site, to prevent electrical shocks.
Do not install the equipment in a place where there is a possibility of combustible gas leaks.
If a combustible gas leaks and remains around the unit, it can cause a fire.
Be sure to install the packing and seal on the installation frame properly. If the packing and seal are not
installed properly, water can enter the room and wet the furniture and floor.
For
integral
units only
Содержание
- Caution in repair 4
- Introduction 4
- Safety cautions 4
- Warning 4
- Cautions regarding products after repair 5
- Domestic air conditioner 5
- Hsu 09 12h03 r qxf introduction 5
- Warning 5
- Caution 6
- Domestic air conditioner 6
- Hsu 09 12h03 r qxf introduction 6
- Warning 6
- Caution 7
- Domestic air conditioner 7
- Hsu 09 12h03 r qxf introduction 7
- Inspection after repair 7
- Warning 7
- Domestic air conditioner 8
- Hsu 09 12h03 r qxf introduction 8
- Icon type of information description 8
- Icons are used to attract the attention of the reader to specific information the meaning of each icon is described in 8
- The table below 8
- Using icons 8
- Using icons list 8
- Functions and control 14
- Main functions and control specifications 14
- Minutes 16
- Hours t 1 hour ts 2 ts 1 1 hours 17
- Off t hour 17
- T ts 3hours 3hours ts 2 ts 3 ts 4 1 hour 17
- Timer function 18
- Function of main thermistor 19
- B25 50 4200k 3 20
- Domestic air conditioner 20
- Indoor unit 20
- R25 23k 3 20
- Room sensor 20
- Value of thermistor 20
- Domestic air conditioner 21
- Hsu 09 12h03 r qxf funtions and control 21
- Domestic air conditioner 22
- Hsu 09 12h03 r qxf funtions and control 22
- Domestic air conditioner 23
- Hsu 09 12h03 r qxf funtions and control 23
- B25 50 3700k 3 24
- Domestic air conditioner 24
- Hsu 09 12h03 r qxf funtions and control 24
- Pipe sensor 24
- R25 10k 3 24
- Domestic air conditioner 25
- Hsu 09 12h03 r qxf funtions and control 25
- Domestic air conditioner 26
- Hsu 09 12h03 r qxf funtions and control 26
- Domestic air conditioner 27
- Hsu 09 12h03 r qxf funtions and control 27
- System configuration 28
- Cautions 29
- Contain no fluorochloric hydrocarbon 29
- Disposal of the old air conditioner 29
- Disposal of the packaging of your new air conditioner 29
- Instruction 29
- Safety instructions and warnings 29
- Cautions 30
- Specifications 30
- The machine is adaptive in following situation 30
- Caution 31
- Cautions 31
- Installation 31
- Safety instruction 31
- Warning 31
- Caution 32
- Cautions 32
- Domestic air conditioner 32
- Hsu 09 12h03 r qxf system configuration 32
- Warning 32
- Indoor unit 33
- Outdoor unit 33
- Parts and functions 33
- Emergency and test operation 46
- Emergency operation 46
- Operation 46
- Removal of the restriction of emergency or test operation 46
- Test operation 46
- For smart use of the air conditioner 47
- Maintenance 47
- Air filter cleaning 48
- Attach the filter 48
- Clean the filter 48
- Close the inlet grille 48
- Do not use the following for cleaning 48
- For smart use of the air conditioner 48
- Indoor body 48
- Maintenance 48
- Open the inlet grille by pulling it upward 48
- Remote controller 48
- Remove the filter 48
- Warning 48
- Maintenance 50
- To keep your air conditioner in good condition after season 50
- Before setting in high season 51
- Caution 51
- Cleaning the standard air filter 51
- Connecting the earthing cable 51
- Do not block the air inlet or outlet 51
- Earthing 51
- Maintenance 51
- No wet hand 51
- Plug in 51
- Before asking for service check the following first 52
- Trouble shooting 52
- Fresh air pipe 1 full energy recovery exchanger 66
- Packing list 66
- Refresh system installation 66
- Bend connector 67
- Full energy recovery exchanger 67
- Room air pipe 67
- According to the drawing install the full energy recovery exchanger on 68
- Installation manual 68
- Outdoor unit cover with the screws 68
- The corresponding place of the outdoor unit and fix the fittings on the 68
- The main unit installation 68
- Pipeline installation 69
- Small size outdoor unit installation sketch 69
- Caution 70
- Power block installation 70
- Indoor unit 71
- Installation of indoor unit 71
- 5 drain pan 81
- 0 outdoor panel 94
- Appendix 104
- Cooling 104
- Heating 104
- Hsu 09 12h03 r qxf appendix 104
- Piping diagrams 104
- Hsu 09 12h03 r qxf appendix 105
- Indoor 105
- Wiring diagrams 105
- Circuit diagram 107
- Circuit diagram 1 107
- Circuit diagram 2 108
- Hsu 09 12h03 r qxf appendix 108
Похожие устройства
- Sc&t HKM02BT Инструкция по эксплуатации
- Sc&t HKM02BR Инструкция по эксплуатации
- Sc&t HKM02BT-4K Инструкция по эксплуатации
- Sc&t HKM02BR-4K Инструкция по эксплуатации
- Sc&t HKM02BPT-4K Инструкция по эксплуатации
- Sc&t HKM02BPR-4K Инструкция по эксплуатации
- Sc&t HE01SER Инструкция по эксплуатации
- Sc&t HE01ERK Инструкция по эксплуатации
- Sc&t HE01ST Инструкция по эксплуатации
- Sc&t HE01SR Инструкция по эксплуатации
- Sc&t HW01 Инструкция по эксплуатации
- Sc&t HE01SI Инструкция по эксплуатации
- Sc&t HE01S Инструкция по эксплуатации
- Sc&t HKM01E Инструкция по эксплуатации
- Sc&t HE03 Инструкция по эксплуатации
- Sc&t HE02EI Инструкция по эксплуатации
- Sc&t HE02EIP Инструкция по эксплуатации
- Sc&t HE02EIX Инструкция по эксплуатации
- Sc&t HE02E Инструкция по эксплуатации
- Sc&t HE02 Инструкция по эксплуатации